20
Chapter 1, Using HP-IB
Overview of the Test Set
Internal Automatic Control Mode
In Internal Automatic Control mode the Test Set’s operation is controlled by an
application program running on the built-in Instrument BASIC (IBASIC)
Controller. The built-in controller runs programs written in IBASIC, a subset of
the Hewlett-Packard BASIC programming language used on the HP 9000 Series
200/300 System Controllers. IBASIC is the only programming language
supported on the built-in IBASIC Controller.
Similarities Between the Test Set’s IBASIC Controller and Other Single-Tasking
Controllers
The architecture of the IBASIC Controller is similar to that of other single-tasking
instrumentation controllers. Only one program can be run on the IBASIC
Controller at any given time. The program is loaded into RAM memory from
some type of mass storage device. Five types of mass storage devices are
available to the Test Set: SRAM memory cards, ROM memory cards, external
disk drives connected to the HP-IB interface, internal RAM disc, and internal
ROM disc. Three types of interfaces are available for connecting to external
instruments and equipment: HP-IB, RS-232, and 16-bit parallel (available as Opt
020 Radio Interface Card).
shows how information is routed inside the Test Set when it is in Internal
Automatic Control mode. In Manual Control mode certain Test Set resources are
dedicated to manual operation. These resources are switched to the IBASIC
Controller when an IBASIC program is running. These include the serial interface
at select code 9, the HP-IB interface at select code 7, the parallel printer interface
at select code 15, and the CRT. In Manual Control mode, front panel information
(instrument settings, measurement results, data input from the DUT) is routed to
the CRT through the To Screen control hardware. In Internal Automatic Control
mode the measurement results and data input from the DUT are routed to the
IBASIC Controller through a dedicated HP-IB interface. Also, in Internal
Automatic Control mode, the CRT is dedicated to the IBASIC Controller for
program and graphics display. This means instrument front panels cannot be
displayed on the CRT when an IBASIC program is running.
Summary of Contents for 8920B
Page 10: ...10 ...
Page 16: ...Contents 16 9 Error Messages Index 673 ...
Page 17: ...17 1 Using HP IB ...
Page 48: ...48 Chapter 1 Using HP IB Remote Local Modes ...
Page 49: ...49 2 Methods For Reading Measurement Results ...
Page 61: ...61 3 HP IB Command Guidelines ...
Page 84: ...84 Chapter 3 HP IB Command Guidelines Guidelines for Operation ...
Page 85: ...85 4 HP IB Commands ...
Page 90: ...90 Adjacent Channel Power ACP ...
Page 116: ...116 Configure I O Configure ...
Page 156: ...156 Call Processing ...
Page 185: ...185 System System SYSTem ERRor Returns integer value quoted string ...
Page 242: ...242 Common Command Descriptions ...
Page 251: ...251 5 Advanced Operations ...
Page 377: ...377 7 IBASIC Controller ...
Page 458: ...458 Chapter 7 IBASIC Controller The TESTS Subsystem ...
Page 640: ...640 Chapter 8 Programming The Call Processing Subsystem Example Programs 11280 SUBEND 11290 ...
Page 643: ...643 9 Error Messages ...
Page 672: ...672 ...
Page 682: ...Index 682 ...