Chapter 7, IBASIC Controller
The IBASIC Controller Screen
The TESTS (IBASIC Controller) screen can be accessed programmatically by sending the
following command:
OUTPUT 714;"DISP TIBasic"
The TESTS (IBASIC Controller) screen is divided into several areas which are
used by the IBASIC controller for different purposes.
The small horizontal rectangle at the top left is the IBASIC command line. As the
name implies IBASIC commands can be executed from this line. Commands can
be entered locally using the rotary knob or remotely using serial port 9. A
maximum of 100 characters may be entered into the command line.
The vertical rectangle at the top right side is the softkey label area. The five
highlighted areas within the softkey label area correspond to the five special
function keys on the front panel of the Test Set. IBASIC programs can assign
tables to these keys and control program execution by using ON KEY interrupts.
The vertical rectangle at the bottom right side is the
To Screen
area and is the
same as the
To Screen
area displayed on any other Test Set screen. The user
may switch to some other Test Set screen by using the rotary knob to position the
cursor onto the desired screen and then pushing the knob.
The large rectangle in the center of the screen is the CRT (display screen) for the
IBASIC controller. The IBASIC controller uses this area for, displaying alpha,
numeric, and graphic information, program editing, program listing and so forth.
This area operates as would the CRT on an external Hewlett-Packard 9000 Series
200/300 Workstation.
Summary of Contents for 8920B
Page 10: ...10 ...
Page 16: ...Contents 16 9 Error Messages Index 673 ...
Page 17: ...17 1 Using HP IB ...
Page 48: ...48 Chapter 1 Using HP IB Remote Local Modes ...
Page 49: ...49 2 Methods For Reading Measurement Results ...
Page 61: ...61 3 HP IB Command Guidelines ...
Page 84: ...84 Chapter 3 HP IB Command Guidelines Guidelines for Operation ...
Page 85: ...85 4 HP IB Commands ...
Page 90: ...90 Adjacent Channel Power ACP ...
Page 116: ...116 Configure I O Configure ...
Page 156: ...156 Call Processing ...
Page 185: ...185 System System SYSTem ERRor Returns integer value quoted string ...
Page 242: ...242 Common Command Descriptions ...
Page 251: ...251 5 Advanced Operations ...
Page 377: ...377 7 IBASIC Controller ...
Page 458: ...458 Chapter 7 IBASIC Controller The TESTS Subsystem ...
Page 640: ...640 Chapter 8 Programming The Call Processing Subsystem Example Programs 11280 SUBEND 11290 ...
Page 643: ...643 9 Error Messages ...
Page 672: ...672 ...
Page 682: ...Index 682 ...