![HP 8920B Programmer'S Manual Download Page 626](http://html.mh-extra.com/html/hp/8920b/8920b_programmers-manual_166189626.webp)
626
Chapter 8, Programming The Call Processing Subsystem
Example Programs
SRQ Example Program
10 ! SRQ_sample program
20 OPTION BASE 1
30 COM /Io_addresses/ INTEGER Inst_addr,Bus_addr
40 COM /Prog_control/ INTEGER Oper_complete,Wait_time,Error_flag
50 !
60 Bus_addr=7 ! Set to 8 when running on 8920
70 Inst_addr=714 ! Set to 814 when running on 8920
80 Wait_time=0 ! Set to minimum of .5 when running on an 8920
90 Oper_complete=0 ! 1 = Operation complete 0 = Operation not
complete
100 Error_flag=0 ! 1 = An error has occurred 0 = no error has
occurred
110 ABORT Bus_addr
120 CLEAR SCREEN
130 PRINTER IS CRT
140 Cnfg_srvc_intrp
150 ON INTR Bus_addr,15 CALL Srvice_interupt
160 ENABLE INTR Bus_addr;2
170 !
180 Start_test:!
190 Cond_test_set
200 OUTPUT Inst_addr;"DISP ACNT"
210 IF NOT FNCnfg_base_sta(0,212,231,5970,-47,"AMPS",321) THEN
Print_error
220 IF FNSet_state("Register") THEN
230 Read_rcdd_data("1234")! Pass the numbers of the RCDD fields
to be read.
240 ELSE
250 Print_error
260 END IF
270 IF NOT FNSet_state("Page") THEN CALL Print_error
280 Meas_carrier
290 IF FNOrder("Power",7) THEN
300 Read_rcdd_data("1")
310 ELSE
320 Print_error
330 END IF
340 OUTPUT Inst_addr;"CALLP:VCH 211;VMAC 4;SAT ’5970HZ’"
350 IF NOT FNSet_state("Handoff") THEN CALL Print_error
360 Meas_sinad
370 IF NOT FNOrder("Mainten",0) THEN CALL Print_error !0 = dummy
variable
380 IF FNOrder("Alert",0) THEN ! 0 = dummy variable to satisfy parm
list
381 BEEP
390 INPUT "Did the phone ALERT? (Y/N)",Yes_no$
400 IF Yes_no$[1,1]="N" OR Yes_no$[1,1]="n" THEN
410 PRINT "Phone failed to ALERT."
420 STOP
Summary of Contents for 8920B
Page 10: ...10 ...
Page 16: ...Contents 16 9 Error Messages Index 673 ...
Page 17: ...17 1 Using HP IB ...
Page 48: ...48 Chapter 1 Using HP IB Remote Local Modes ...
Page 49: ...49 2 Methods For Reading Measurement Results ...
Page 61: ...61 3 HP IB Command Guidelines ...
Page 84: ...84 Chapter 3 HP IB Command Guidelines Guidelines for Operation ...
Page 85: ...85 4 HP IB Commands ...
Page 90: ...90 Adjacent Channel Power ACP ...
Page 116: ...116 Configure I O Configure ...
Page 156: ...156 Call Processing ...
Page 185: ...185 System System SYSTem ERRor Returns integer value quoted string ...
Page 242: ...242 Common Command Descriptions ...
Page 251: ...251 5 Advanced Operations ...
Page 377: ...377 7 IBASIC Controller ...
Page 458: ...458 Chapter 7 IBASIC Controller The TESTS Subsystem ...
Page 640: ...640 Chapter 8 Programming The Call Processing Subsystem Example Programs 11280 SUBEND 11290 ...
Page 643: ...643 9 Error Messages ...
Page 672: ...672 ...
Page 682: ...Index 682 ...