Read PC failed during break (603)
Cause: System failure or target condition.
Action: Try again.
Record checksum failure (400)
Cause: During a transfer operation, the checksum specified in a file did not
agree with that calculated by the HP 64700.
Action: Retry the transfer operation. If the failure is repeated, make sure
that both your host and the HP 64700 data communications parameters are
configured correctly.
Records expected: %s; records received: %s (401)
Cause: The HP 64700 received a different number of records than it
expected to receive during a transfer operation.
Action: Retry the transfer. If the failure is repeated, make sure that the data
communications parameters are set correctly on the host and on the
HP 64700.
Register access aborted (630)
Cause: Occurs when a <CTRL>c is entered during register display.
Register class cannot be modified: %s (637)
Cause: You tried to modify a register class instead of an individual register.
Action: You can only modify individual registers. Refer to the display
registers command description for a list of register names.
Register not writable: %s (636)
Cause: This error occurs when you attempt to modify a read only register.
Action: If this error occurs, you cannot modify the contents of the register
with the modify register command.
Error Messages
475
Summary of Contents for 64782
Page 2: ...User s Guide for the Graphical User Interface HP 64782 MC6833x Emulation Analysis ...
Page 22: ...Part 1 Quick Start Guide 21 ...
Page 24: ...1 Getting Started 23 ...
Page 50: ...Part 2 User s Guide 49 ...
Page 52: ...2 Plugging into a Target System 51 ...
Page 54: ...3 Starting and Exiting HP 64700 Interfaces 53 ...
Page 64: ...4 Entering Commands 63 ...
Page 94: ...5 Configuring the Emulator 93 ...
Page 133: ...132 ...
Page 134: ...6 Using the Emulator 133 ...
Page 194: ...7 Using the Emulation Analyzer 193 ...
Page 255: ...254 ...
Page 256: ...8 Making Software Performance Measurements 255 ...
Page 290: ...9 Using the External State Analyzer 289 ...
Page 303: ...302 ...
Page 304: ...10 Making Coordinated Measurements 303 ...
Page 321: ...320 ...
Page 322: ...11 Setting X Resources 321 ...
Page 336: ...Part 3 Reference 335 ...
Page 337: ...Descriptions of the product in a dictionary or encyclopedia format Part 3 336 ...
Page 338: ...12 Emulator Analyzer Interface Commands 337 ...
Page 415: ...set Emulator Analyzer Interface Commands set 414 ...
Page 429: ... SYMB Emulator Analyzer Interface Commands SYMB 428 ...
Page 445: ...444 ...
Page 446: ...13 Error Messages 445 ...
Page 489: ...488 ...
Page 490: ...Part 4 Concept Guide 489 ...
Page 491: ...Topics that explain concepts and apply them to advanced tasks Part 4 490 ...
Page 492: ...14 Concepts 491 ...
Page 507: ...506 ...
Page 508: ...Part 5 Installation Guide 507 ...
Page 509: ...Instructions for installing and configuring the product Part 5 508 ...
Page 510: ...15 Installation 509 ...
Page 527: ...526 ...
Page 528: ...16 Installing Updating Emulator Firmware 527 ...
Page 535: ...534 ...
Page 539: ...538 ...
Page 549: ...548 ...