use
display trace
to display the contents of the trace memory. If a previous
trace list is on screen, the current trace automatically updates the display. If
the trace memory contents exceed the page size of the display, the <NEXT>,
<PREV>, <Up arrow>, or <Down arrow> keys may be used to display all the
trace memory contents. You also can press <CTRL>f and <CTRL>g to move
the display left and right.
You can set up trigger and storage qualifications using the
specify trace
command. The analyzers will begin tracing when a
cmb_execute
command
executes, which causes an EXECUTE signal on the Coordinated
Measurement Bus.
The analyzer will trace any state by default.
The parameters are as follows:
again
This option repeats the previous trace measurement. It also begins a trace
measurement with a newly loaded trace specification. (Using trace without
the again parameter will start a trace with the default specification rather
than the loaded specification.)
anything
This causes the analyzer to capture any type of information.
arm_trig2
This option allows you to specify the external trigger as a trace qualifier, for
coordinating measurements between multiple HP 64700s, or an HP 64700
and another instrument.
Before arm_trig2 can appear as an option, you must modify the emulation
configuration interactive measurement specification. When doing this, you
must specify that either BNC or CMBT drive trig2, and that the analyzer
receive trig2. See the chapter on "Making Coordinated Measurements" for
more information.
break_on_trigger
This stops target system program execution when the trigger is found. The
emulator begins execution in the emulation monitor. When using this option,
the on_halt option cannot be included in the command.
modify_command
This recalls the last trace command that was executed.
on_halt
When using this option, the analyzer will continue to capture states until the
emulation processor halts or until a stop_trace command is executed. When
this option is used, the break_on_trigger, repetitively, and TRIGGER options
cannot be included in the command.
only
This option allows you to qualify the states that are stored, as defined by
QUALIFIER.
prestore
This option instructs the analyzer to save specific states that occur prior to
states that are stored (as specified with the "only" option).
QUALIFIER
This determines which of the traced states will be stored or prestored in the
trace memory for display upon completion of the trace. Events can be
Emulator/Analyzer Interface Commands
trace
437
Summary of Contents for 64782
Page 2: ...User s Guide for the Graphical User Interface HP 64782 MC6833x Emulation Analysis ...
Page 22: ...Part 1 Quick Start Guide 21 ...
Page 24: ...1 Getting Started 23 ...
Page 50: ...Part 2 User s Guide 49 ...
Page 52: ...2 Plugging into a Target System 51 ...
Page 54: ...3 Starting and Exiting HP 64700 Interfaces 53 ...
Page 64: ...4 Entering Commands 63 ...
Page 94: ...5 Configuring the Emulator 93 ...
Page 133: ...132 ...
Page 134: ...6 Using the Emulator 133 ...
Page 194: ...7 Using the Emulation Analyzer 193 ...
Page 255: ...254 ...
Page 256: ...8 Making Software Performance Measurements 255 ...
Page 290: ...9 Using the External State Analyzer 289 ...
Page 303: ...302 ...
Page 304: ...10 Making Coordinated Measurements 303 ...
Page 321: ...320 ...
Page 322: ...11 Setting X Resources 321 ...
Page 336: ...Part 3 Reference 335 ...
Page 337: ...Descriptions of the product in a dictionary or encyclopedia format Part 3 336 ...
Page 338: ...12 Emulator Analyzer Interface Commands 337 ...
Page 415: ...set Emulator Analyzer Interface Commands set 414 ...
Page 429: ... SYMB Emulator Analyzer Interface Commands SYMB 428 ...
Page 445: ...444 ...
Page 446: ...13 Error Messages 445 ...
Page 489: ...488 ...
Page 490: ...Part 4 Concept Guide 489 ...
Page 491: ...Topics that explain concepts and apply them to advanced tasks Part 4 490 ...
Page 492: ...14 Concepts 491 ...
Page 507: ...506 ...
Page 508: ...Part 5 Installation Guide 507 ...
Page 509: ...Instructions for installing and configuring the product Part 5 508 ...
Page 510: ...15 Installation 509 ...
Page 527: ...526 ...
Page 528: ...16 Installing Updating Emulator Firmware 527 ...
Page 535: ...534 ...
Page 539: ...538 ...
Page 549: ...548 ...