Using Trigger Signals
The HP 64700 contains two internal lines, trig1 and trig2, over which trigger
signals can pass from the emulator or analyzer to other HP 64700s on the
Coordinated Measurement Bus (CMB) or other instruments connected to the
BNC connector.
You can configure the internal lines to make connections between the
emulator, analyzer, external analyzer (if its configured as an independent
state or timing analyzer), CMB connector, or BNC connector. Measurements
that depend on these connections are called
interactive measurements
or
coordinated measurements
.
This figure below illustrates the possible connections between the internal
lines (trig1 and trig2) and the emulator, analyzer, and external devices.
Note that the "External Analyzer" connection for "Trig2" is only available if
you have selected "state" or "timing" for the external analyzer mode.
Notice that the analyzer always drives trig1, and the emulator always receives
trig1. This provides for the
break_on_trigger
syntax of the
trace
command.
Figure 30
313
Summary of Contents for 64782
Page 2: ...User s Guide for the Graphical User Interface HP 64782 MC6833x Emulation Analysis ...
Page 22: ...Part 1 Quick Start Guide 21 ...
Page 24: ...1 Getting Started 23 ...
Page 50: ...Part 2 User s Guide 49 ...
Page 52: ...2 Plugging into a Target System 51 ...
Page 54: ...3 Starting and Exiting HP 64700 Interfaces 53 ...
Page 64: ...4 Entering Commands 63 ...
Page 94: ...5 Configuring the Emulator 93 ...
Page 133: ...132 ...
Page 134: ...6 Using the Emulator 133 ...
Page 194: ...7 Using the Emulation Analyzer 193 ...
Page 255: ...254 ...
Page 256: ...8 Making Software Performance Measurements 255 ...
Page 290: ...9 Using the External State Analyzer 289 ...
Page 303: ...302 ...
Page 304: ...10 Making Coordinated Measurements 303 ...
Page 321: ...320 ...
Page 322: ...11 Setting X Resources 321 ...
Page 336: ...Part 3 Reference 335 ...
Page 337: ...Descriptions of the product in a dictionary or encyclopedia format Part 3 336 ...
Page 338: ...12 Emulator Analyzer Interface Commands 337 ...
Page 415: ...set Emulator Analyzer Interface Commands set 414 ...
Page 429: ... SYMB Emulator Analyzer Interface Commands SYMB 428 ...
Page 445: ...444 ...
Page 446: ...13 Error Messages 445 ...
Page 489: ...488 ...
Page 490: ...Part 4 Concept Guide 489 ...
Page 491: ...Topics that explain concepts and apply them to advanced tasks Part 4 490 ...
Page 492: ...14 Concepts 491 ...
Page 507: ...506 ...
Page 508: ...Part 5 Installation Guide 507 ...
Page 509: ...Instructions for installing and configuring the product Part 5 508 ...
Page 510: ...15 Installation 509 ...
Page 527: ...526 ...
Page 528: ...16 Installing Updating Emulator Firmware 527 ...
Page 535: ...534 ...
Page 539: ...538 ...
Page 549: ...548 ...