Eye
,
Mask
and
Eyeline
Mode
Measurement
T
utorials
Making
Eye
Diagram
Measurements
Making
the
measurement
F
our
active
eye
measurements
may
be
simultaneously
displayed
at
the
bottom
left
side
of
the
instrument
display
.
Previously
setup
measurements
remain
active
as
new
measurements
are
added
to
the
bottom
of
the
list.
As
these
new
measurements
are
made
,
the
list
scrolls
up
.
If
a
fth
measurement
is
added,
the
rst
measurement
is
deactivated
and
the
measurement
is
scrolled
o
the
display
.
T
o
access
the
eye
measurements
described
at
the
beginning
of
this
section,
press:
4
Shift
5
NNNNNNNNNNNNNNNNNNNNNNNNNN
Meas
Eye
A
column
of
softkeys
on
the
right
side
of
the
instrument's
screen,
titled
\Measure
eye ",
is
displayed.
N
O
T
E
Eye
parametric
measurements
are
made
from
histogram
analysis
of
the
instrument's
database
,
rather
than
directly
on
the
active
channel.
T
o
make
these
measurements,
the
color
grade
displa
y
mode
must
be
turned
on.
When
selecting
a
measurement
from
the
NNNNNNNNNNNNNNNNNNNNNNNNNN
Meas
Eye
menu,
the
instrument
will
automatically
turn
on
the
color
grade
mode
,
if
it
is
not
already
activated.
When
selecting
a
measurement
from
the
choices
above
the
numeric
ke
ypad,
the
user
must
turn
on
color
grade
prior
to
activating
the
measurement.
N
O
T
E
Only
one
channel
at
a
time
should
be
active
to
make
e
ye
measurements
and
other
measurements
on
the
color
grade
database
.
5-9
Summary of Contents for 54750A
Page 1: ...User s Guide HP 83480A Analyzer HP 54750A Oscilloscope ...
Page 6: ...NOTE Clean the cabinet using a damp cloth only vi ...
Page 7: ...X Ray Radiation Notice vii ...
Page 8: ...Declaration of Conformity viii ...
Page 17: ...Figure0 1 Exampleof astatic safeworkstation xvii ...
Page 28: ......
Page 43: ...1 The Instrument at a Glance ...
Page 57: ...The Rear Panel Figure1 3 Theinstrument rearpanel 1 15 ...
Page 60: ...TheInstrument ataGlance ...
Page 61: ...2 General Purpose Keys ...
Page 69: ...3 Speci cations and Characteristics ...
Page 76: ...Speci cationsand Characteristics ...
Page 77: ...4 Calibration Overview ...
Page 84: ...CalibrationOverview ...
Page 85: ...5 Eye Mask and Eyeline Mode Measurement Tutorials ...
Page 136: ...Eye Mask andEyelineModeMeasurement Tutorials ...
Page 137: ...6 The Digital Communications Analysis Menus ...
Page 173: ...The Digital Communications Analysis Menus MeasureEyeMenu Figure6 7 Crossing measurement 6 37 ...
Page 178: ...The Digital Communications Analysis Menus MeasureEye Menu Figure6 11 MeasuringQ factor 6 42 ...
Page 191: ...7 Waveform Measurements ...
Page 211: ...8 Making Automatic Measurements ...
Page 233: ...9 Increasing Measurement Accuracy and Time Interval Measurement ...
Page 252: ...IncreasingMeasurement Accuracy andTime Interval Measurement ...
Page 253: ...10 General Purpose Oscilloscope Menus ...
Page 317: ...11 The General Function Menus ...
Page 345: ...The General Function Menus DisplayMenu Figure11 3 Connecteddots 11 29 ...
Page 415: ...12 Messages ...
Page 421: ...13 How the Instrument Works ...
Page 453: ...Index ...