The
Digital
Communications
Analysis
Menus
Time
Base
Menu
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
Time
base
windowing...
The
Time
Base
Windowing
function
is
similar
to
the
delayed
sweep
on
analog
oscilloscopes
because
it
turns
on
an
expanded
time
base
.
This
expanded
time
base
allows
you
to
pinpoint
and
to
horizontally
expand
a
portion
of
the
signal
for
a
more
detailed
or
high
resolution
analysis
.
It
can
also
help
you
to
make
custom
automatic
measurements
.
A
utomatic
measurements
are
made
on
the
rst
occurrence
of
the
event
on
the
display
.
The
windowing
feature
allows
you
to
isolate
individual
events
on
the
display
for
the
automatic
measurement.
K
ey
Path
4
Time
base
5
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
Time
base
windowing...
enable
NNNNNNNNNNNNNN
View
View
lets
you
select
main
or
window
.
The
Main
function
displays
the
signal
according
to
the
scale
and
position
settings
,
and
a
window
marker
is
placed
on
the
signal.
The
window
marker
denes
the
portion
of
the
signal
you
plan
to
expand.
However
,
the
color
highlight
is
not
available
when
mask
testing
is
turned
on.
The
default
color
of
the
window
marker
is
red,
but
you
can
change
the
window
marker
color
in
the
Display
menu.
The
Window
function
expands
and
displays
the
portion
of
the
signal
that
is
outlined
by
the
window
marker
.
The
amount
of
expansion
depends
on
the
window
scale
and
window
position
settings
.
K
ey
Path
4
Time
base
5
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
Time
base
windowing...
enable
NNNNNNNNNNNNNN
View
main
or
window
NNNNNNNNNNNNNNNNNNNNNNNNNNNNN
Time
Base
The
Window
Scale
function
controls
the
length
of
the
window
marker
,
and
the
maximum
window
scale
setting
is
100%
of
full
screen.
The
window
marker
determines
how
much
of
the
signal
is
expanded
in
the
window
mode
.
Increasing
the
window
scale
decreases
the
amount
of
expansion.
K
ey
Path
4
Time
base
5
N
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
Time
base
windowing...
enable
N
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
Window
scale
6-48
Summary of Contents for 54750A
Page 1: ...User s Guide HP 83480A Analyzer HP 54750A Oscilloscope ...
Page 6: ...NOTE Clean the cabinet using a damp cloth only vi ...
Page 7: ...X Ray Radiation Notice vii ...
Page 8: ...Declaration of Conformity viii ...
Page 17: ...Figure0 1 Exampleof astatic safeworkstation xvii ...
Page 28: ......
Page 43: ...1 The Instrument at a Glance ...
Page 57: ...The Rear Panel Figure1 3 Theinstrument rearpanel 1 15 ...
Page 60: ...TheInstrument ataGlance ...
Page 61: ...2 General Purpose Keys ...
Page 69: ...3 Speci cations and Characteristics ...
Page 76: ...Speci cationsand Characteristics ...
Page 77: ...4 Calibration Overview ...
Page 84: ...CalibrationOverview ...
Page 85: ...5 Eye Mask and Eyeline Mode Measurement Tutorials ...
Page 136: ...Eye Mask andEyelineModeMeasurement Tutorials ...
Page 137: ...6 The Digital Communications Analysis Menus ...
Page 173: ...The Digital Communications Analysis Menus MeasureEyeMenu Figure6 7 Crossing measurement 6 37 ...
Page 178: ...The Digital Communications Analysis Menus MeasureEye Menu Figure6 11 MeasuringQ factor 6 42 ...
Page 191: ...7 Waveform Measurements ...
Page 211: ...8 Making Automatic Measurements ...
Page 233: ...9 Increasing Measurement Accuracy and Time Interval Measurement ...
Page 252: ...IncreasingMeasurement Accuracy andTime Interval Measurement ...
Page 253: ...10 General Purpose Oscilloscope Menus ...
Page 317: ...11 The General Function Menus ...
Page 345: ...The General Function Menus DisplayMenu Figure11 3 Connecteddots 11 29 ...
Page 415: ...12 Messages ...
Page 421: ...13 How the Instrument Works ...
Page 453: ...Index ...