Eye
,
Mask
and
Eyeline
Mode
Measurement
T
utorials
Making
Eye
Diagram
Measurements
Adjusting
the
vertical
scale
3.
T
o
adjust
the
vertical
scale
,
press:
4
Channel
5
(on
the
front-panel
of
the
plug-in
module)
N
NNNNNNNNNNNNNNNNNNNNNN
Display
on
4.
T
o
perform
an
optical
transmitter
compliance
measurement,
activate
the
lter
to
set
the
channel
bandwidth
by
pressing:
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
Bandwidth/wavelength...
NNNNNNNNNNNNNNNNNNNN
Filter
on
NNNNNNNNNNNNNN
Done
5.
T
o
adjust
the
vertical
scale
,
press:
NNNNNNNNNNNNNNNNN
Scale
A
djust
the
scale
for
a
four
division
data
display
,
by
using
the
arrow
keys
located
next
to
the
knob
.
Selecting
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
Channel
autoscale
will
generally
give
you
the
same
results
.
Selecting
the
time
base
6.
T
o
select
the
time
base
,
press:
4
Time
base
5
NNNNNNNNNNNNNNNNN
Units
bit
period
(HP
83480A
only)
7.
Select
the
bit
rate
of
your
transmitter
.
F
or
this
example
,
select
2.48832
GHz
STM16/OC48.
NNNNNNNNNNNNNNNNNNNNNNNNNN
Bit
rate
(HP
83480A
only)
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
2.48832
GHz
Use
the
arrow
keys
to
select
the
desired
rate
.
8.
Scale
the
waveform
to
show
two
complete
crossings
(refer
to
Figure
5-2)
by
pressing:
NNNNNNNNNNNNNNNNN
Scale
A
djust
the
display
with
the
arrow
keys
,
the
keypad,
or
the
knob
.
9.
T
o
center
the
waveform
on
the
instrument
display
,
press:
NNNNNNNNNNNNNNNNNNNNNNNNNN
Position
A
djust
the
display
with
the
arrow
keys
,
the
keypad,
or
the
knob
.
5-7
Summary of Contents for 54750A
Page 1: ...User s Guide HP 83480A Analyzer HP 54750A Oscilloscope ...
Page 6: ...NOTE Clean the cabinet using a damp cloth only vi ...
Page 7: ...X Ray Radiation Notice vii ...
Page 8: ...Declaration of Conformity viii ...
Page 17: ...Figure0 1 Exampleof astatic safeworkstation xvii ...
Page 28: ......
Page 43: ...1 The Instrument at a Glance ...
Page 57: ...The Rear Panel Figure1 3 Theinstrument rearpanel 1 15 ...
Page 60: ...TheInstrument ataGlance ...
Page 61: ...2 General Purpose Keys ...
Page 69: ...3 Speci cations and Characteristics ...
Page 76: ...Speci cationsand Characteristics ...
Page 77: ...4 Calibration Overview ...
Page 84: ...CalibrationOverview ...
Page 85: ...5 Eye Mask and Eyeline Mode Measurement Tutorials ...
Page 136: ...Eye Mask andEyelineModeMeasurement Tutorials ...
Page 137: ...6 The Digital Communications Analysis Menus ...
Page 173: ...The Digital Communications Analysis Menus MeasureEyeMenu Figure6 7 Crossing measurement 6 37 ...
Page 178: ...The Digital Communications Analysis Menus MeasureEye Menu Figure6 11 MeasuringQ factor 6 42 ...
Page 191: ...7 Waveform Measurements ...
Page 211: ...8 Making Automatic Measurements ...
Page 233: ...9 Increasing Measurement Accuracy and Time Interval Measurement ...
Page 252: ...IncreasingMeasurement Accuracy andTime Interval Measurement ...
Page 253: ...10 General Purpose Oscilloscope Menus ...
Page 317: ...11 The General Function Menus ...
Page 345: ...The General Function Menus DisplayMenu Figure11 3 Connecteddots 11 29 ...
Page 415: ...12 Messages ...
Page 421: ...13 How the Instrument Works ...
Page 453: ...Index ...