The
General
Function
Menus
Disk
Menu
T
ext
V
erbose
denitions
Type
Type
describes
how
the
waveform
was
acquired:
raw
,
average
,
or
versus
.
When
this
eld
is
read
back
into
the
instrument,
all
the
modes
,
except
versus
,
are
converted
to
raw
.
The
default
value
is
raw
.
P
oints
P
oints
indicates
the
number
of
data
points
contained
in
the
waveform
record.
The
number
of
points
is
set
by
the
Record
Length
softkey
in
the
A
cquisition
menu.
The
default
value
is
calculated.
Count
Count
represents
the
minimum
number
of
hits
at
each
time
bucket
in
the
waveform
record
when
the
waveform
was
created
using
an
ensemble
acquisition
mode
,
like
averaging.
F
or
example
,
when
averaging,
a
count
of
four
would
mean
every
waveform
data
point
in
the
waveform
record
has
been
averaged
at
least
four
times
.
Count
is
ignored
when
it
is
read
back
into
the
instrument.
The
default
value
is
1.
XInc
X
increment
is
the
time
duration
between
data
points
on
the
X-axis
.
X
increment
is
equal
to
the
YData
range
value
for
versus
waveforms
.
The
default
value
is
calculated.
XOrg
X
origin
is
the
x-value
of
the
rst
data
point
in
the
data
record.
X
origin
is
equal
to
the
YData
center
value
for
versus
waveforms
.
The
default
value
is
22E-9.
XRef
X
reference
is
always
set
to
zero
when
it
is
read
back
into
the
instrument.
The
default
value
is
0.
YData
range
Y
data
range
is
the
full
voltage
range
covered
by
the
A/D
converter
.
If
this
eld
is
omitted,
it
is
calculated
when
read
back
into
the
instrument.
The
default
value
is
calculated.
YData
center
YData
center
is
voltage
level
at
the
center
of
the
YData
range
.
If
this
eld
is
omitted,
it
is
calculated
when
read
back
into
the
instrument.
The
default
value
is
0,
but
value
is
calculated.
Coupling
Coupling
is
ignored
when
it
is
read
back
into
the
instrument.
The
default
value
is
dc
50.
XRange
XRange
is
the
time
duration
across
10
horizontal
divisions
of
the
display
.
The
default
value
is
1.00000E-001.
XOset
XOset
is
the
time
at
the
left
edge
of
the
display
.
The
default
value
is
22E-9.
11-17
Summary of Contents for 54750A
Page 1: ...User s Guide HP 83480A Analyzer HP 54750A Oscilloscope ...
Page 6: ...NOTE Clean the cabinet using a damp cloth only vi ...
Page 7: ...X Ray Radiation Notice vii ...
Page 8: ...Declaration of Conformity viii ...
Page 17: ...Figure0 1 Exampleof astatic safeworkstation xvii ...
Page 28: ......
Page 43: ...1 The Instrument at a Glance ...
Page 57: ...The Rear Panel Figure1 3 Theinstrument rearpanel 1 15 ...
Page 60: ...TheInstrument ataGlance ...
Page 61: ...2 General Purpose Keys ...
Page 69: ...3 Speci cations and Characteristics ...
Page 76: ...Speci cationsand Characteristics ...
Page 77: ...4 Calibration Overview ...
Page 84: ...CalibrationOverview ...
Page 85: ...5 Eye Mask and Eyeline Mode Measurement Tutorials ...
Page 136: ...Eye Mask andEyelineModeMeasurement Tutorials ...
Page 137: ...6 The Digital Communications Analysis Menus ...
Page 173: ...The Digital Communications Analysis Menus MeasureEyeMenu Figure6 7 Crossing measurement 6 37 ...
Page 178: ...The Digital Communications Analysis Menus MeasureEye Menu Figure6 11 MeasuringQ factor 6 42 ...
Page 191: ...7 Waveform Measurements ...
Page 211: ...8 Making Automatic Measurements ...
Page 233: ...9 Increasing Measurement Accuracy and Time Interval Measurement ...
Page 252: ...IncreasingMeasurement Accuracy andTime Interval Measurement ...
Page 253: ...10 General Purpose Oscilloscope Menus ...
Page 317: ...11 The General Function Menus ...
Page 345: ...The General Function Menus DisplayMenu Figure11 3 Connecteddots 11 29 ...
Page 415: ...12 Messages ...
Page 421: ...13 How the Instrument Works ...
Page 453: ...Index ...