General
Purpose
Oscilloscope
Menus
FFT
Menu
Figure
10-4.
An
FFT
display
.
Y
ou
may
also
notice
that
there
are
three
horizontal
lines
of
numbers
below
the
graticule
area.
The
rst
line
lists
the
horizontal
scale
and
position
settings
of
the
time
domain.
The
second
line
lists
the
vertical
and
horizontal
settings
of
the
FFT
.
It
is
labeled
\FT"
for
F
ourier
transform.
The
third
line
lists
the
vertical
scale
and
oset
settings
of
channel
2.
Because
the
frequency
domain
may
be
new
to
you,
let's
look
at
the
second
line
of
numbers
.
The
rst
number
is
the
vertical
scale
in
dB/div
.
The
second
number
is
the
oset
in
dBm
at
the
center
of
the
lower
graticule
area.
The
third
number
is
the
horizontal
scale
in
frequency/div
.
The
fourth
number
is
the
center
frequency
value
.
T
o
maximize
the
use
of
the
display
area,
some
of
the
instrument's
features
share
the
lower
area
of
the
display
.
The
vertical
settings
and
automatic
measurement
results
share
the
same
area
of
the
display;
the
marker
results
,
statistics
results
,
and
the
horizontal
settings
of
the
frequency
domain
share
the
same
area
of
the
display
.
10-30
Summary of Contents for 54750A
Page 1: ...User s Guide HP 83480A Analyzer HP 54750A Oscilloscope ...
Page 6: ...NOTE Clean the cabinet using a damp cloth only vi ...
Page 7: ...X Ray Radiation Notice vii ...
Page 8: ...Declaration of Conformity viii ...
Page 17: ...Figure0 1 Exampleof astatic safeworkstation xvii ...
Page 28: ......
Page 43: ...1 The Instrument at a Glance ...
Page 57: ...The Rear Panel Figure1 3 Theinstrument rearpanel 1 15 ...
Page 60: ...TheInstrument ataGlance ...
Page 61: ...2 General Purpose Keys ...
Page 69: ...3 Speci cations and Characteristics ...
Page 76: ...Speci cationsand Characteristics ...
Page 77: ...4 Calibration Overview ...
Page 84: ...CalibrationOverview ...
Page 85: ...5 Eye Mask and Eyeline Mode Measurement Tutorials ...
Page 136: ...Eye Mask andEyelineModeMeasurement Tutorials ...
Page 137: ...6 The Digital Communications Analysis Menus ...
Page 173: ...The Digital Communications Analysis Menus MeasureEyeMenu Figure6 7 Crossing measurement 6 37 ...
Page 178: ...The Digital Communications Analysis Menus MeasureEye Menu Figure6 11 MeasuringQ factor 6 42 ...
Page 191: ...7 Waveform Measurements ...
Page 211: ...8 Making Automatic Measurements ...
Page 233: ...9 Increasing Measurement Accuracy and Time Interval Measurement ...
Page 252: ...IncreasingMeasurement Accuracy andTime Interval Measurement ...
Page 253: ...10 General Purpose Oscilloscope Menus ...
Page 317: ...11 The General Function Menus ...
Page 345: ...The General Function Menus DisplayMenu Figure11 3 Connecteddots 11 29 ...
Page 415: ...12 Messages ...
Page 421: ...13 How the Instrument Works ...
Page 453: ...Index ...