COMMISSIONING
Part No.: 4417340 Revision 1
Service Manual
143
954 SmartServo FlexLine
7.3.8.4.4 Commissioning Parameters for All Types of Probes
Engauge *Product temperature* Tab
☛
The following entities
can
be set set by
Engauge
or
HART
SmartView
for a specific functioning of the FII-RTD module in an
instrument. The default values are available after initialization of the
non-volatile memory; so check each entity for its correctness.
Name
Explanation
Value Range
Default
[Product immersion depth]
The minimum required
product level distance
above an element before
this element is taken into
account in the average
product temperature
calculation
floating point number:
<-x.x .. +x.x>
<0.5>
[Hysteresis]
This is a hysteresis
mechanism distance
around the switching points
of the elements that are
taken into account in the
calculation.
floating point number:
<-x.x .. +x.x>
<0.1>
[High high alarm]
[High alarm]
[Low alarm]
[Low low alarm]
4 thresholds for activating a
related alarm status in the
Primary Value
floating point numbers:
<-x.x .. +x.x>
<1.0E22>
[Alarm test enable]
Enables (
if
activated, see
next listed entity) the
simulation of one of the 4
alarms for a minute, by
simulating the actual
measured Primary Value is
slightly below or above the
alarm threshold.
<Enable>
<Disable>
<disable>
[Alarm test]
Activates and selects at the
same time the Alarm test (if
enabled with the
[Alarm test
enable]
listed before, and the
4 alarm thresholds are
properly set).
<No Alarm>
<High-high alarm>
<High alarm>
<Low alarm>
<Low-low alarm>
<No Alarm>
[Function identification]
The current module’s
function name. This
function is visible on the
HART SmartView
di l
13 characters
<Product temp.>
[Element offset]
Each element can
individually be given an
offset.
floating point numbers:
<-x.x .. +x.x>
<0.0>
Summary of Contents for FlexLine SmartServo 954
Page 1: ...Service Manual 954 SmartServo FlexLine ...
Page 197: ...COMMISSIONING Part No 4417340 Revision 1 Service Manual 189 954 SmartServo FlexLine ...
Page 202: ...COMMISSIONING 194 Service Manual Part No 4417340 Revision 1 954 SmartServo FlexLine ...
Page 203: ...COMMISSIONING Part No 4417340 Revision 1 Service Manual 195 954 SmartServo FlexLine ...
Page 300: ...APPENDIX A 292 Service Manual Part No 4417340 Revision 1 954 SmartServo FlexLine ...
Page 302: ...APPENDIX B 294 Service Manual Part No 4417340 Revision 1 954 SmartServo FlexLine ...