OPERATION
248
Service Manual
Part No.: 4417340 Revision 1
954 SmartServo FlexLine
Entity name
Entity name
(SmartView)
Description
[Freeze]
[Freeze]
(Product level)
The displacer remains in its position even when the level
reaches the displacer position.
[Block]
[Block]
(Product level)
The displacer stops at its present position, and
depending on the status of entity [Block mode], the
displacer will only move up with an increasing level, or
the block is cancelled when the level reaches the
displacer position
The displacer will remain in its position until an unlock command is
given.
Entity [Block mode] must be set (checked) at commissioning (or at a
later stage):
Entity name
Description
[Block mode]
Continuous (default) or Non-continuous
Continuous:
when the level reaches the displacer position,
the displacer will follow the increasing level
Non-continuous:
the block mode is cancelled when the level
reaches the displacer position
8.4
Unlock
The Unlock command cancels any operational command.
Entity name
Entity name
(SmartView)
Description
[Unlock]
[Unlock]
(Product level)
Cancels any operational command.
Summary of Contents for FlexLine SmartServo 954
Page 1: ...Service Manual 954 SmartServo FlexLine ...
Page 197: ...COMMISSIONING Part No 4417340 Revision 1 Service Manual 189 954 SmartServo FlexLine ...
Page 202: ...COMMISSIONING 194 Service Manual Part No 4417340 Revision 1 954 SmartServo FlexLine ...
Page 203: ...COMMISSIONING Part No 4417340 Revision 1 Service Manual 195 954 SmartServo FlexLine ...
Page 300: ...APPENDIX A 292 Service Manual Part No 4417340 Revision 1 954 SmartServo FlexLine ...
Page 302: ...APPENDIX B 294 Service Manual Part No 4417340 Revision 1 954 SmartServo FlexLine ...