
Appendix
BC-200 Manual
– P/N DOC-01-013
124
9.7 M
ODEM
/P
RINTER
/HLI I
NTERFACE
9
9
.
.
7
7
.
.
1
1
M
M
O
O
D
D
E
E
M
M
I
I
N
N
T
T
E
E
R
R
F
F
A
A
C
C
E
E
The BC-200 PC Interface can be used to control the FIP using a modem and BC-200 PCI software. A global
option on the FIP will enable/disable modem operation.
9.7.1.1
PC M
ODEM
Any non software modem should work correctly with the PCI. It is recommended to use a high quality external
modem to allow modifying of modem parameters to solve any possible compatibility issues.
9.7.1.2
FIP M
ODEM
The recommended modem for the FIP is a NetComm IG6000 (industrial modem) that is modified to work with
24VDC. This modem was chosen due to its construction and reliability.
9.7.1.3
FIP M
ODEM
S
ETTINGS
The FIP modem needs to be programmed with the following AT commands using a terminal program such as
HyperTerminal and the standard modem to PC cable provided:
Use “AT S0=2 R115 &K3 &S0 %E2” command to set the required modem options
ATS0=2
- answer after 2 rings
ATR115
- lock terminal speed to 115000
AT&K3
- RTS/CTS flow control
AT&S0
- DSR signal always asserted
AT%E2
- Automatic speed stepping
To establish connection with the modem after the above commands have been entered, set HyperTerminal port
settings to 115 baud rate & RTS/CTS handshaking.
After re-connecting to the modem using the above settings, save the configuration to hardware profile 0 using the
AT&W0
command.
Check modem configuration using
AT&V
command. Ensure that all the options are the same as the configuration
printout below:
B0 E1 L1 M1 T Q0
R115
V1 W2 X5 &B4 &C1 &D2 &G0 &H0
&K3
&L0 &M0 &N1 &P1 &R0
&S0
&T4 &X0 &Y0 \A3 \B3 \J0 \K5 \N3 \T0 \V0 \X0 #A2 #B0 #C0 #D0 #E0 #F0 #I0 #J1
#M0 #N0 #O0 #Q0 #U0 #V0 %B0 %C3 %D0
%E2
%F1 %G0 %H0 %K0 %L11 %M0 %N0 %P0 %R0
%S0 %T0 %U0 %V0 %W0 *K0 *V0 *R0 *T0 *Y0 -Q1 :E1 -SDR0,1 #CID0 #MUS0
S000:002
S002:043 S003:013 S004:010 S005:008 S006:004 S007:050 S008:004
S009:006 S010:018 S011:095 S012:050 S018:000 S025:005 S026:000 S030:000
S033:003 S042:002 S043:015 S045:098 S047:030 S066:010 S067:042 S069:060
S076:080 S077:010 S105:030 S110:004 S126:061
&Z0 =
&Z1 =
&Z2 =
&Z3 =
&Z4 =
&Z5 =
&Z6 =
&Z7 =
&Z8 =
&Z9 =
Last dialled = T2
+MS: 12,1,300,56000,1,0
Access Security: OFF Security Database, Security Mode & Call-Log Erase: FREE
Stored Phone Numbers: DISPLAYED OutDial: ENABLED
Caller ID: DISABLED
DES: 64bit
Internal Storage (#MEM): Enabled when DTR off: 4 Voice Messages
#ALM1=0,
#ALM2=0, PIN number =1234
Summary of Contents for BC-200
Page 1: ...BC 200 OPERATION INSTALLATION PROGRAMMING MANUAL P N DOC 01 013 ECN11 0058 23 Aug 12 Rev 5 07 ...
Page 138: ...Appendix BC 200 Manual P N DOC 01 013 138 9 12 PANEL EXPANSION RELAYS ...
Page 142: ...Appendix BC 200 Manual P N DOC 01 013 142 9 9 1 13 3 4 4 R RE EL LA AY Y M MO OD DU UL LE E ...
Page 144: ...Appendix BC 200 Manual P N DOC 01 013 144 9 9 1 13 3 6 6 Z ZO ON NE E M MO OD DU UL LE E ...
Page 155: ......