Data Storage (cont’d)
Using Storage Mode
On the Legacy panel, enter and leave Engineer mode, so the External RS232 module is recognised. Then re-
enter Engineer mode to use the storage mode facilities.
On the Legacy panel, enter menu
56.2.4=Communications.RS232.Copy/Overwrite
.
To copy the programming data FROM the Legacy panel TO the Grade 3 panel, select
1=Copy Site
. To
copy the programming data FROM the Grade 3 panel TO the Legacy panel, select
2=Overwrite Site
.
Press
1
to start the copy procedure, or
2
to abort at any time. The copy procedure can also be aborted by
pressing
esc
on the Grade 3 panel; this exits Storage mode.
NOTE:
The copy procedure is started as soon as the option is selected; neither panel requests confirmation
before proceeding.
During the copy procedure, the display on the affected keypad on the Grade 3 panel will show a message
indicating which data elements are being copied (Users, Parameters, etc).
Leaving Storage Mode
At any time, Storage mode can be exited by pressing
esc
on the Grade 3 panel. It is recommended that the
panels be separated before this is done, although doing so is not necessary. If the panels remain connected
while the Grade 3 panel is not in Storage mode, behaviour on line 2 of the Grade 3 panel and line 1 of the
Legacy panel cannot be guaranteed.
Summary of Contents for 3-144
Page 1: ...Honeywell Security Galaxy 3 48C 3 144 3 144C 3 520 3 520C Programming Manual ...
Page 2: ......
Page 8: ...Galaxy 3 Series Programming Manual 2 ...
Page 30: ...Galaxy 3 Series Programming Manual 24 ...
Page 184: ...Galaxy 3 Series Programming Manual 178 ...
Page 188: ...Galaxy 3 Series Programming Manual A 4 ...
Page 202: ...Galaxy 3 Series Programming Manual C 2 ...
Page 212: ...2 Galaxy 3 Series Programming Manual ...