Galaxy 3 Series Programming Manual
7
Setting the System
R = Ready
F = Fault (group is unset and at least 1
zone is open
P = Part Set
S (flashing) = selected for setting
S (steady) = already set
L = Group is locked out and cannot be unset.
- = Group is not available to the user
Section 3: Setting Options
Setting the System Using a PIN
Full Setting
Enter:
USER
CODE + A
If groups are enabled and the user code has been assigned group choice then the keypad displays the set
status of the available groups:
Pressing the keys for the groups toggles the
R
(
Ready
)
to an
S (
set flashing).
NOTE:
If using the Galaxy 3-520 system the groups are displayed in blocks of eight. Each block can be
viewed by pressing the A or B keys.
Once the required groups have been selected press the
ent
key to begin the setting procedure.
If groups are not enabled or the user does not have group choice, entering the user code followed by the
A
key immediately starts the setting procedure.
The keypad displays the exit time countdown. At the end of the exit time, or when the setting procedure is
terminated by a
FINAL
or
PUSH-SET
zone closing, the
ENTRY/EXIT HORN
outputs and keypad buzz-
ers become silent for four seconds, then emit two long tones to confirm that the system is set. The message
SYSTEM IS SET
appears briefly before the keypad display changes back to the normal day banner.
Part Setting
Enter:
CODE + B
This is identical to the
Full Setting
procedure, except the keypad display indicates that the system is being
Part Set
. Only the zones which have the
Part
attribute enabled (refer to option
52.5 = PROGRAM
ZONE.Part
), are included.
Cancelling the Setting
The full and part setting routines can be aborted by pressing the
esc
key (on the keypad used to begin setting)
before the system sets.
TIMED
TIMED
TIMED
TIMED
TIMED
060
060
060
060
060
PART SET
PART SET
PART SET
PART SET
PART SET
060
060
060
060
060
SET A12345678
SET A12345678
SET A12345678
SET A12345678
SET A12345678
Groups RRSRSSSS
Groups RRSRSSSS
Groups RRSRSSSS
Groups RRSRSSSS
Groups RRSRSSSS
SET A12345678
SET A12345678
SET A12345678
SET A12345678
SET A12345678
Groups SSSRR---
Groups SSSRR---
Groups SSSRR---
Groups SSSRR---
Groups SSSRR---
Summary of Contents for 3-144
Page 1: ...Honeywell Security Galaxy 3 48C 3 144 3 144C 3 520 3 520C Programming Manual ...
Page 2: ......
Page 8: ...Galaxy 3 Series Programming Manual 2 ...
Page 30: ...Galaxy 3 Series Programming Manual 24 ...
Page 184: ...Galaxy 3 Series Programming Manual 178 ...
Page 188: ...Galaxy 3 Series Programming Manual A 4 ...
Page 202: ...Galaxy 3 Series Programming Manual C 2 ...
Page 212: ...2 Galaxy 3 Series Programming Manual ...