Galaxy 3 Series Programming Manual
100
53 - Program Outputs (cont’d)
Link
outputs can be activated by any of the link option sources. The operation of the
Link
output is depend-
ent on the
Output Mode
and
Groups
assigned to the output. The
Groups
assigned to the
Link
must have at
least one group common to the link output, if that output is to be activated. This feature can be used to multi-
ply the number of different link outputs available on the system.
NOTE:
When a zone function is the source of a
Link
output type, then a point to point link is available and
is as effective as direct wiring.
66 RF Jam (Latch)
The RF Jam output is activated whenever any of the RF RIO’s configured onto the system detect a significant
level of interference to cause radio jamming.
67 RF Super (Latch)
The RF Supervision
output is activated whenever there is a supervision failure from any one of the super-
vised RF detectors configured onto the system. That is, when the system has received no signals (including
periodic check-in signals) whatsoever, from a particular detector within the programmed supervision period.
68 Bell Fail
The
Bell Fail
output activates whenever a zone causes a fault condition.
69 Low Volts
The
Low Volts
output activates when the voltage of the AUX outputs drops below 10V.
70 Lockout (Reflex)
The
Lockout
output is active between the
ON
and
OFF
times assigned to the
Lockout Status
(option
65.3.6=TIMERS.Autoset.Lockout Status
). The
Lockout
output mode is
Reflex,
therefore it remains
active until the lockout switches
OFF.
71 Vibration Test (Pulse)
The
Vibration Test
function is used to test zones programmed as
Vibration.
This output is used in conjunc-
tion with
Precheck
(menu option
66 – Pre-Check: - Mode: 4 – Forced Check
). The Vibration Test output
sends a five second positive removed pulse to the vault sensors. Any sensor not activated by the test is re-
ported by the pre-check function and prevents the system from setting.
72 – 75 ATM-1, ATM-2, ATM-3, ATM-4 (Reflex)
The relevant
ATM
output is activated when the respective
ATM
zone type is omitted. This output is a
Reflex
output and follows the omit status of the
ATM
zone types.
76 Fault (Latch)
This output will activate any time there is a fault condition present on the panel and will clear when all the fault
conditions have cleared.
The following fault types will activate the fault output:
Line fail (any module), ARC comms fail (any module), RF jam, RF low battery, RF supervision failure, Bell fail
(from a bell fail zone), AC fail (panel, AC zone or power supply), Battery fail (panel, battery zone or power
supply).
SMS signalling faults will not activate the fault outputs.
Summary of Contents for 3-144
Page 1: ...Honeywell Security Galaxy 3 48C 3 144 3 144C 3 520 3 520C Programming Manual ...
Page 2: ......
Page 8: ...Galaxy 3 Series Programming Manual 2 ...
Page 30: ...Galaxy 3 Series Programming Manual 24 ...
Page 184: ...Galaxy 3 Series Programming Manual 178 ...
Page 188: ...Galaxy 3 Series Programming Manual A 4 ...
Page 202: ...Galaxy 3 Series Programming Manual C 2 ...
Page 212: ...2 Galaxy 3 Series Programming Manual ...