Galaxy 3 Series Programming Manual
46
3 = EXT Telecoms
0 = Direct Access
See INT Telecoms description
1 – 5 = Call Back 1 – 5
(see Telecoms description)
2. Send Alarms
Option not available
3. Call Galaxy
Option not available
4. Auto Service
The Galaxy 3 Series panels can be programmed to automatically initiate communications to remote servicing
software, under three circumstances:
•
If any site programming has changed the panel will automatically send the new programming to the
downloader.
•
On a predetermined schedule the panel can activate an automatic periodic upload.
•
On a predetermined schedule the panel can activate an automatic remote routine inspection.
NOTE:
The Auto Service function works for both the Internal Telecomms and Ethernet module.
The following sub options allow the engineer to select the mode of the automatic communication in each of the
three situations. These options are not available to users.
1 = Mode
This selects the mode of the automated connection following a change to the panel programming. There are
four modes:
0 = Off
In this mode the panel will not automatically initiate a remote servicing call even if the panel programming has
changed. This is the default setting.
1 = Timed
In this mode, following modification to panel programming, a remote servicing call will be initiated automati-
cally between a programmed
start time
(option 47.4.2.1)
and
end time
(option 47.4.2.2). To avoid traffic
congestion the panel selects a random time between the start and end times to initiate the call. Once the
connection is made, the new panel programming will be uploaded to the remote servicing package.
2 = Instant
In this mode, following modification to panel programming, the connection to the remote servicing package is
initiated immediately, using call back number 1, on exiting engineering mode. Once the connection is made, the
new programming will be uploaded to the remote servicing package.
47 - Remote Access (cont’d)
Summary of Contents for 3-144
Page 1: ...Honeywell Security Galaxy 3 48C 3 144 3 144C 3 520 3 520C Programming Manual ...
Page 2: ......
Page 8: ...Galaxy 3 Series Programming Manual 2 ...
Page 30: ...Galaxy 3 Series Programming Manual 24 ...
Page 184: ...Galaxy 3 Series Programming Manual 178 ...
Page 188: ...Galaxy 3 Series Programming Manual A 4 ...
Page 202: ...Galaxy 3 Series Programming Manual C 2 ...
Page 212: ...2 Galaxy 3 Series Programming Manual ...