Refer to Appendix C of this manual for the detailed breakdown of the SIA event structure for each level.
On selecting the SIA format, the keypad prompts for the required SIA level to be entered, there are five SIA
levels available:
•
Level 0 (default) – basic event information with 4 digit account numbers
•
1 – as level 0 plus 6 digit account numbers
•
2 – as level 1 but with event modifiers
•
3 – as level 2 but with text descriptors
•
4 – as level 3 but also enables the SIA control command feature (refer option 08 SIA control)
1 = Trigger Events
When the SIA level has been selected press the
ent
key. The keypad displays the first trigger event and it’s
On/Off status (see
table 25
for the list of available triggers, and
Appendix B
for the events which are
controlled by each trigger). The triggers control the events, which are transmitted. If the trigger is set to On,
any events logged, which are controlled by the trigger will be transmitted. If the trigger is set to Off, the
events controlled by the trigger will not be transmitted. Step through the trigger events using the A and B
keys.
1 = Status
To modify the trigger on/off status select the trigger to be modified using the
A
and
B
keys and press the
ent
key. To program the status to
On
press
1
, to set it to
Off
press
0
. Alternatively use the
A/B
keys to
toggle between
On
and
Off
. To accept the new status, press the
ent
key. This will automatically return
the display to the previous menu level.
Programming the SIA format with groups enabled
If groups have been enabled on the system (refer to option 63.1), then the SIA format menu alters slightly to
support the independent event trigger programming for each group.
1 = Trigger Events
On selecting the SIA level the menu enters the Trigger Events option. Press the ent key to display the first
trigger event; the keypad shows the trigger, the trigger status and the groups assigned.
To modify the trigger event select the required event using the
A
and
B
keys and press the
ent
key. The
1=Status option is then displayed. If the status requires to be modified press the
ent
key.
1 = Status
To program the status to
On
press
1
, to set it to
Off
press
0
. Alternatively use the
A/B
keys to toggle
between
On
and
Off
. To accept the new status, press the
ent
key. This will automatically return the
display to the previous menu level.
2 = Groups
If groups have been enabled on the system (refer option 63.1), then the groups can be assigned to each
event trigger. This means that the events have to occur in assigned groups before they are signalled. To
modify the groups assigned to a specific trigger press the ent key from the 2=Groups menu option. The
display will show the groups and indicate whether it is assigned (Y) or not assigned (N) to the group. To
assign or unassign a group from a specific trigger press the number key corresponding to the group
number. The display will show the new status. To accept the new status, press the ent key and return to
the previous menu level. If the Galaxy panel supports more than 8 groups use the
A
and
B
keys to
scroll through all available groups.
Summary of Contents for 3-144
Page 1: ...Honeywell Security Galaxy 3 48C 3 144 3 144C 3 520 3 520C Programming Manual ...
Page 2: ......
Page 8: ...Galaxy 3 Series Programming Manual 2 ...
Page 30: ...Galaxy 3 Series Programming Manual 24 ...
Page 184: ...Galaxy 3 Series Programming Manual 178 ...
Page 188: ...Galaxy 3 Series Programming Manual A 4 ...
Page 202: ...Galaxy 3 Series Programming Manual C 2 ...
Page 212: ...2 Galaxy 3 Series Programming Manual ...