Galaxy 3 Series Programming Manual
99
42 Illegal Code (Latch)
The
Illegal Code
is activated 60 seconds after an entry of a single
Dual Code
or a code which is entered
outwith the
Timer A
and/or
Timer B
times assigned to it in menu option
42.1.4=CODES.User
Codes.Time Zone.
43 Max Tamp (Latch)
The MAX TAMP output is activated when a MAX, MicroMAX or MAX
3
tamper is activated.
44 Abort (Latch)
The ABORT output is activated when a valid code is entered during the Abort period on system entry.
45 Unset
The
Unset
output is activated each time the system (or group) is unset. The default
output mode
attribute is
programmed as pulse, for two seconds. This can be used to activate a buzzer to notify a user that the system
has been unset, when using an RF fob.
46 Set Late (Latch)
The
Set Late
output is activated if the system has not been set by the programmed
Monitor
time – refer to
option
65.3.1=TIMERS.Autoset.Status
.
47 U/S Early (Latch)
The
Unset Early
output is activated if the system has been unset before the programmed
Monitor
time –
refer to option
65.3.1=TIMERS.Autoset.Status.
48 Prewarn (Reflex)
The
Prewarn
output is active during the programmed prewarning period of the autoset function. The mode is
Reflex
. The
Prewarn
emits a constant tone if the autosetting of the system can be extended. If an extension
is not possible, the
Prewarn
output pulses.
49 Autoset (Reflex)
The
Autoset
output is activated when the system has been set by the autoset function – refer to option
65.3=TIMERS.Autoset
. The default
Output Mode
attribute is programmed as Reflex, therefore the output
remains active until the system unsets.
NOTE:
The
Set
is also activated when the system autosets.
50 DR. Masked
The DR. (detector) Masked output is activated when
zones, programmed for zone activity checks, are not
activated in the unset state within the time period or set/unset cycles programmed in Parameter 51.61
.
The
zones are programmed for activity in menu 52.8.
51 – 65 Link A – O (Reflex)
Link output types have no inherent function: they are designed for use with option
54 = LINKS
to provide the
engineer with a means of activating a specific output address.
53 - Program Outputs (cont’d)
Summary of Contents for 3-144
Page 1: ...Honeywell Security Galaxy 3 48C 3 144 3 144C 3 520 3 520C Programming Manual ...
Page 2: ......
Page 8: ...Galaxy 3 Series Programming Manual 2 ...
Page 30: ...Galaxy 3 Series Programming Manual 24 ...
Page 184: ...Galaxy 3 Series Programming Manual 178 ...
Page 188: ...Galaxy 3 Series Programming Manual A 4 ...
Page 202: ...Galaxy 3 Series Programming Manual C 2 ...
Page 212: ...2 Galaxy 3 Series Programming Manual ...