Galaxy 3 Series Programming Manual
D-4
Event Log (cont’d)
NOTE:
M = Mandatory. NM = Non-Mandatory
NOTE:
A plus (+) means an event has started. A negative (-) means an event has finished.
KEYPAD TEXT
DESCRIPTION
Trigger Event
LOC WRITE
Diagnostics local write event
None
M
LOC
Lockout timer activated.
None
NM
LOCKTIMER –
Lockout timer de-activated.
None
NM
+ LOG
Log zone activated (opened).
16. Log
NM
– LOG
Log zone de-activated (closed).
16. Log
NM
LOG 90%
Event log 90% full
Always TR
NM
LOG DELAY
Log Delay zone has been activated (opened) for longer than the Delay Alarm time.
16. Log
NM
+ LOW RES
Zone changing to low resistance (900 to 800 Ohm).
15. Trouble
M
– LOW RES
Zone changing from Low Resistance to Normal Closed (800 to 900 Ohm).
15. Trouble
M
LOW VOLTS+
Voltage of AUX outputs has dropped below 10V.
13. Elec Status
15. Trouble
M
+ MASK
Mask zone activated (opened).
4. Security
M
– MASK
Mask zone de-activated (closed).
4. Security
18. Zone restoral
M
MASKED
Zone masked. Detector has activated its masking output.
15. Trouble
20. Fault
M
MAX ALARM
MAX alarm — door forced.
4. Security
17. Max Tag
M
MAX TAMP
MAX Tamper
9. Tamper
M
MEM RESET
Memory Reset (Restart) to factory default settings (Cold Start).
13. Elec Status
NM
MEMORY OK
Memory Reset (Restart) with programming details saved (Warm start).
13. Elec Status
NM
M
Module Missing its AB (RS485) communications.
9. Tamper
M
MISSING –
Module that was Missing now has its AB (RS485) communications re-established.
9. Tamper
18. Zone restoral
M
MOD CODES
Modify Codes menu (Menu Option 42) has been accessed.
14. Menu Access
M
MOD REM
Galaxy Gold menu (Menu Option 47) has been accessed.
14. Menu Access
NM
MOD SUMMR
Modify Summer menu (Menu Option 43) has been accessed.
14. Menu Access
NM
MOD T/D
Modify Time/Date menu (Menu Option 42) has been accessed.
14. Menu Access
M
MOD TMRS
Modify Timers Control menu (Menu Option 45) has been accessed.
14. Menu Access
NM
NEW T/D
New Time/Date after modification.
Always TR
M
OMIT ATM1
Omit all ATM1 zones.
8. Omit
M
OMIT ATM2
Omit all ATM2 zones.
8. Omit
M
OMIT ATM3
Omit all ATM3 zones.
8. Omit
M
OMIT ATM4
Omit all ATM4 zones.
8. Omit
M
OMIT VIBS
Mass omit of vibration zones.
8. Omit
M
OMIT ZONE
Omit zones menu (menu option 0 in Quick Menu or menu option 11 in Full Menu has been
accessed.
None
M
OMITTED
Zone has been omitted
8. Omit
M
OVERRIDE
Event has been overridden to set the system
None
M
OVWR SITE
Remote overwrite of the site has occured via galaxy gold or RS232 module
None
M
P.AUDIBLE
PA Audible zone activated (opened).
None
NM
PA
PA zone activated (opened)
1. PA/Duress
M
Summary of Contents for 3-144
Page 1: ...Honeywell Security Galaxy 3 48C 3 144 3 144C 3 520 3 520C Programming Manual ...
Page 2: ......
Page 8: ...Galaxy 3 Series Programming Manual 2 ...
Page 30: ...Galaxy 3 Series Programming Manual 24 ...
Page 184: ...Galaxy 3 Series Programming Manual 178 ...
Page 188: ...Galaxy 3 Series Programming Manual A 4 ...
Page 202: ...Galaxy 3 Series Programming Manual C 2 ...
Page 212: ...2 Galaxy 3 Series Programming Manual ...