Galaxy 3 Series Programming Manual
B-4
Ev
SIA Event
Galaxy Log
Galaxy Log Event
Ev Type Galaxy
Contact
Description Event
Description
Trigger
ID Event
VIDEO
Video zone tested
ZONE
NOT SENT
611
VIDEO EXT
Video exit zone tested
ZONE
NOT SENT
611
INT DELAY
Intrud delay zone tested
ZONE
NOT SENT
611
SEC DELAY
Security del zone tested
ZONE
NOT SENT
611
SET LOG
Set Log zone tested
ZONE
NOT SENT
611
CUSTOM A
Custom A zone tested
ZONE
NOT SENT
611
CUSTOM B
Custom B zone tested
ZONE
NOT SENT
611
EXITGUARD
Exitguard zone tested
ZONE
NOT SENT
611
MASK
Mask zone tested
ZONE
NOT SENT
611
URGENT
Urgent zone tested
ZONE
NOT SENT
611
PA UNSET
PA unset zone tested
ZONE
NOT SENT
611
KSW RESET
Ksw. reset zone tested
ZONE
NOT SENT
611
VIBRATION
Vibration zone tested
ZONE
NOT SENT
611
ATM-1
ATM-1 zone tested
ZONE
NOT SENT
611
ATM-2
ATM-2 zone tested
ZONE
NOT SENT
611
ATM-3
ATM-3 zone tested
ZONE
NOT SENT
611
ATM-4
ATM-4 zone tested
ZONE
NOT SENT
611
ALARM EXT
Alarm extend zone test.
ZONE
NOT SENT
611
SOAK TEST
Soak test zone act
ZONE
NOT SENT
611
C - Closing
CA
Closing Report
FULL SET
Automatic Set
EVENT
10.SETTING
401
CE
Closing Extend
EXTENSION
Auto arm exten. delay
USER
10.SETTING
464
PREWARN
Auto arm prewarn delay
MISC
NEVER TR
464
CG
Close Area
PART SET
Part set by user
USER
10.SETTING
441
KSW P/SET
Part set by user
KSSET
10.SETTING
442
CI
Fail to Set
FAIL SET
Fail to Set
EVENT
7. SET FAULT 454
CJ
Late to Set
LATE SET
Late to Set
EVENT
10.SETTING
454
CL
Closing Report
FULL SET
Full set
USER
10.SETTING
401
FULL SET
Set by keypad
EVENT
10.SETTING
401
KSW SET
Keyswitch set
ZONE
10.SETTING
409
CP
Auto. Closing
REARM
Rearm after alarm
EVENT
10.SETTING
463
CR
Recent Close
RECEN.SET
Previous alarm was within 5 mins of set
EVENT
2.INTRUDER 459
CT
Late to Open
TIMEOUT
Entry timeout
EVENT
10.SETTING
None
D - Access
DD
Acces Denied
Invalid Card
MAX tag unknown
MOD.
17.MAXTAG
421
DF
Door Forced
MAX ALARM
Door contact broken
MOD.
4.SECURITY
423
17.MAXTAG
DG
Acces Granted
LEGAL CD
Legal code entered
USER
16.LOG
462
LEGAL CD
ATM code entered
USER
16.LOG
462
Valid
MAX tag accepted
USER
17.MAXTAG
422
DK
Acces Lockout
ILL-CODE
Illegal code entry
USER
16.LOG
421
REJECT CARD
Illegal MAX tag
USER
17.MAXTAG
421
FOB REJECT
Illegal Fob
ZONE
10.SETTING
421
DT
Door propped
DOOR PROP
MAX - Door left open
MOD.
4.SECURITY
426
Event Codes (cont’d)
Summary of Contents for 3-144
Page 1: ...Honeywell Security Galaxy 3 48C 3 144 3 144C 3 520 3 520C Programming Manual ...
Page 2: ......
Page 8: ...Galaxy 3 Series Programming Manual 2 ...
Page 30: ...Galaxy 3 Series Programming Manual 24 ...
Page 184: ...Galaxy 3 Series Programming Manual 178 ...
Page 188: ...Galaxy 3 Series Programming Manual A 4 ...
Page 202: ...Galaxy 3 Series Programming Manual C 2 ...
Page 212: ...2 Galaxy 3 Series Programming Manual ...