Galaxy 3 Series Programming Manual
97
24 Batt Test
This output is activated when a battery load test is in progress. Refer to option
61.1.4 = Diagnostics.Latest.PSU Comms.
25 Wrong CD
This output is activated whenever a wrong code alarm occurs. That is, when six wrong codes in succession
are entered at the keypad. The output, by default pulses on for 90 seconds.
26 Alert (Latch)
The
Alert
output is activated when the control panel loses communication with one of the remote modules or
keypads.
27 Fire Delay (Latch)
The
Fire Delay
output is activated whenever a
Fire
zone is activated. The activation of the output is delayed
subject to the period determined by the
03=Abort Time
parameter. The
Fire Delay
output is not subject to
the
Rearm
parameter: it latches on and remains active until a valid code (type 2 or above) is entered.
28 No Re-Arm (Latch)
The
No Rearm
output is activated on a full alarm event during the set state: it is subject to the
Bell Delay
parameter. The
No Rearm
output is similar to the strobe output, but it stays on at the end of the bell time,
until unset.
29 Timer A (Reflex)
The
Timer-A
output is controlled by the
Timer-A
option (refer to option
65=Timers A/B
) and activates in
accordance with the programmed on and off times assigned to the function.
30 Timer B (Reflex)
The
Timer-B
output is controlled by the
Timer-B
option (refer to option
65=Timers A/B
) and activates in
accordance with the programmed on and off times assigned to the function.
NOTE:
If the TIMER A or B outputs are programmed as LATCH mode, then they can only be reset by a
user code with access to all of the groups assigned to the relevant timer.
31 Walk Test (Reflex)
The
Walk Test
output is activated when a zone included in the walk test is tested (refer to option
31=Walk
Test
).
32 Zone Omit (Reflex)
The
Zone Omit
ouput is activated as soon as a zone is omitted from the system by option
11=OMIT
ZONES
or by option
54=LINKS
. If the
Output Mode
attribute is assigned as:
•
Reflex
(default) the output remains active until the zone is reinstated;
•
Latch
the output is reset on entry of a valid code.
53 - Program Outputs (cont’d)
Summary of Contents for 3-144
Page 1: ...Honeywell Security Galaxy 3 48C 3 144 3 144C 3 520 3 520C Programming Manual ...
Page 2: ......
Page 8: ...Galaxy 3 Series Programming Manual 2 ...
Page 30: ...Galaxy 3 Series Programming Manual 24 ...
Page 184: ...Galaxy 3 Series Programming Manual 178 ...
Page 188: ...Galaxy 3 Series Programming Manual A 4 ...
Page 202: ...Galaxy 3 Series Programming Manual C 2 ...
Page 212: ...2 Galaxy 3 Series Programming Manual ...