Galaxy 3 Series Programming Manual
66
51 - Parameters (cont’d)
49 = Confirm Time
This option is the maximum time between two separate zones for a confirmed alarm to be generated up to a
maximum of
99
minutes, which is equivalent to the complete set period, with a default of
30
minutes.
50 = RF Bat Delay
This option allows a warning to be given at the Galaxy panel if an RF low battery is detected. An additional
option is given at the panel that allows a delay up to a maximum of
100
hours (default) before a signal of
RF
BAT LOW
is sent to the
ARC.
51 = RF Jam Delay
This option allows the RF RIO to send an RF jam signal to the Galaxy panel if it detects interference for 30
seconds. If the interference is continuously present for five minutes (default), the signal is transmitted to central
station. The programmable range is 0 - 30 minutes.
52 = RF Stop Set
If this option is enabled, the setting is prevented if all supervised devices have not signalled to the receiver in
the stop set period prior to setting. This is selectable from
0 - 250
minutes. The default is
20
minutes.
53 = RF Stop Mode
This option controls if and how an RF fault prevents the panel from being set. There are three options:
0 = Disabled:
An RF fault will not prevent setting
1 = Warning:
If there is a failure the user will get a warning but can continue to set.
2 = Auto Check:
If there is a failure the system cannot be set until the zone(s) have been activated.
54 = Keypad Access
This option allows the keypad to unset the system. There are two options:
1 = Always
2 = Except Entry:
Except when entry time is running. This ensures that users are unsetting using a fob or
MAX tag (portable device)
55 = Confirm
This option controls how confirmed alarms are generated. It controls the operation of confirm outputs plus the
signalling of confirmed alarms. There are three options:
1 = Operation:
This option controls when confirmed alarms can be triggered. An entry timeout alarm will
never contribute to a confirmed alarm. Here are three options:
1 = Before Entry (UK)
. Confirmed alarms can be triggered before starting entry time only.
2 = Except entry
. Confirmed alarms can be triggered any time except during the entry delay period.
3 = Always (EU)
. Confirmed alarms are always enabled.
2 = Entry Timeout:
This option controls whether exit type zones can cause confirmed alarms, after an entry
timeout.
0 = Disable Exits
. Exit type zones will only cause unconfirmed intruder alarms. They will not contribute
to the two activations required for a confirmed alarm.
1 = Enable Exits
. After the expiry of the entry delay, activation of an exit type zone will be identical to an
intruder zone.
Summary of Contents for 3-144
Page 1: ...Honeywell Security Galaxy 3 48C 3 144 3 144C 3 520 3 520C Programming Manual ...
Page 2: ......
Page 8: ...Galaxy 3 Series Programming Manual 2 ...
Page 30: ...Galaxy 3 Series Programming Manual 24 ...
Page 184: ...Galaxy 3 Series Programming Manual 178 ...
Page 188: ...Galaxy 3 Series Programming Manual A 4 ...
Page 202: ...Galaxy 3 Series Programming Manual C 2 ...
Page 212: ...2 Galaxy 3 Series Programming Manual ...