Document No: C-61-00003-3
Figure 4-16 Example of AGV’s scanning area which can travel in both the direction (Top view)
4.9 Area protection (Mobile, Horizontal, 4 Units Interconnected, Variable
Area)
For AGVs travelling in all directions it is possible to use 4 interconnected units of UAMs mounted on
each side of AGV. Safety can be improved by switching each unit to the area with appropriate size and shape
based on the speed and direction of travel. Further, it is also possible to use incremental encoder in such
systems for area switching.
Figure 4-17 Example of AGV’s scanning area which can travel in all the direction (Top view)
Protection zone
Warning zone 1
Warning zone2
Protection zone
Warning zone 1
Warning zone 2
Summary of Contents for UAM-05LP
Page 1: ... Document No C 61 00003 3 ...
Page 104: ... Document No C 61 00003 3 Figure 7 33 b Function Figure7 33 c Area ...
Page 107: ... Document No C 61 00003 3 Figure 7 36 a Project report tab Figure 7 36 b Error report tab ...
Page 148: ... Document No C 61 00003 3 13 External dimension 13 1 UAM 05LP ...