Document No: C-61-00003-3
Table 3-7 Response time for different scan skip settings
Master-Slave function disabled
Scan skip count
Off Response time (ms)
1
90
150
210
270
330
390
450
510
2
120
210
300
390
480
3
150
270
390
510
Scan skip count
On Response time (ms)
1
270
330
390
450
510
2
300
390
480
3
270
390
510
Master-Slave function enabled
Scan skip count
Off Response time (ms)
1
150
210
270
330
390
450
510
2
180
270
360
450
3
210
330
450
Scan skip count
On Response time (ms)
1
330
390
450
510
2
360
450
3
330
450
3.20 Optical Window Contamination Warning Function
This is a function to warn the optical window contamination by blinking the 7-segment display number
before contamination level reaches the maximum limit causing the OSSD signals to switch to OFF state.
Cleaning the optical window at the blinking stage will prevent the unnecessary stop due to contamination
error. No specific configuration is necessary to activate this function.
Summary of Contents for UAM-05LP
Page 1: ... Document No C 61 00003 3 ...
Page 104: ... Document No C 61 00003 3 Figure 7 33 b Function Figure7 33 c Area ...
Page 107: ... Document No C 61 00003 3 Figure 7 36 a Project report tab Figure 7 36 b Error report tab ...
Page 148: ... Document No C 61 00003 3 13 External dimension 13 1 UAM 05LP ...
Page 149: ... Document No C 61 00003 3 13 2 Base mounting bracket ...
Page 150: ... Document No C 61 00003 3 13 3 Rear mounting bracket ...
Page 151: ... Document No C 61 00003 3 13 4 Cover Protection Bracket ...
Page 152: ... Document No C 61 00003 3 14 EC Declaration of conformity ...
Page 153: ... Document No C 61 00003 3 ...