Document No: C-61-00003-3
Table 4-1 Default values for selected applications
Applications
Sensing
Interlock
Reference
Monitoring
(Tolerance)
Off response time
(Common to all areas)
Minimum
detection width
Active
areas
Start/Restart
Setting
Delay
General
70mm
1
-
-
-
150ms
Access protection
(Horizontal application Stationary)
70mm
1
Manual/Auto
1s
-
150ms
Access protection
(Vertical application- whole body detection)
70mm
1
Manual/Auto
1s
Used
(100mm)
90ms
Access protection
(Vertical application Stationary)
30mm
1
Manual/Auto
1s
Used
(100mm)
90ms
AGV
70mm
32
-
-
-
120ms
*Check the settings for each function and verify that they match the system requirements. Modify the values
if necessary.