3.9.3 Muting override function
Muting override is a function to recover UAM when the OSSD is switched to OFF state due to muting
related errors by temporarily suspending the safety function. Override function is active when the override
input (OVERRIDE 1/2) and the reset input (RESET 1/2) are switched in a sequence.
Figure 3-21 shows the
override sequence.
Override start conditions
▶
At least
one of the muting inputs is in ON-state.
▶
Object is present in the protection zone.
▶
Time interval between override input and reset input is within 0.03s to 1s (T3).
Override stop conditions
▶
Both muting inputs are in OFF-state.
▶
Override input or reset input is in OFF-state.
▶
When predefined maximum override time T4 exceeds.
▶
Error is detected by self-diagnostic function of the UAM.
▶
During override state when area is switched to the other area.
Maximum override period (T4)
Maximum override period can be selected from one of these values
▶
1 minute
▶
6 minutes
▶
12 minutes
Figure 3-21 Override Sequence
Summary of Contents for UAM-05LP
Page 1: ... Document No C 61 00003 3 ...
Page 104: ... Document No C 61 00003 3 Figure 7 33 b Function Figure7 33 c Area ...
Page 107: ... Document No C 61 00003 3 Figure 7 36 a Project report tab Figure 7 36 b Error report tab ...
Page 148: ... Document No C 61 00003 3 13 External dimension 13 1 UAM 05LP ...
Page 149: ... Document No C 61 00003 3 13 2 Base mounting bracket ...
Page 150: ... Document No C 61 00003 3 13 3 Rear mounting bracket ...
Page 151: ... Document No C 61 00003 3 13 4 Cover Protection Bracket ...
Page 152: ... Document No C 61 00003 3 14 EC Declaration of conformity ...
Page 153: ... Document No C 61 00003 3 ...