Document No: C-61-00003-3
4.6 Area protection (Mobile, Horizontal, Single Protection, Variable Area)
For applications where AGV travels in a single direction, it is possible to switch to different areas at
corners for effectively monitoring the obstacles at front (Figure 4-14).
Left turn
Straight
Right turn
Figure 4-14 one example of AGV scanning area at curve (Top view)
Protection zone
Warning zone1
Warning zone 2
Summary of Contents for UAM-05LP