5. Installation
Cautions during the installation of UAM are explained in this chapter.
5.1 Light interference
UAM uses pulsed laser for object detection. Light sources
in the surrounding
could interfere with its
operation leading to false detection. User should examine the surroundings environments before installing
the UAM. Some of the light sources that could interfere with UAM are as below.
Incandescent light
Fluorescent light
Stroboscopic light
Flashing beacon
Sunlight
Infrared light sources
In case the light source cannot be avoided during the operation, UAM should be installed with the light
source located at ±5 degrees or more from the detection plane to prevent the interference (Figure 5.1).
Figure 5-1 Installation to avoid light interference
User should perform risk assessment for light interference in the
working
environment before the installation.
Avoid direct light such as stroboscopic, flashing beacon, fluorescent.
Failing to comply with the above could lead to critical injury or death.
User should verify detection capability before actual operation.
Summary of Contents for UAM-05LP
Page 1: ... Document No C 61 00003 3 ...
Page 104: ... Document No C 61 00003 3 Figure 7 33 b Function Figure7 33 c Area ...
Page 107: ... Document No C 61 00003 3 Figure 7 36 a Project report tab Figure 7 36 b Error report tab ...
Page 148: ... Document No C 61 00003 3 13 External dimension 13 1 UAM 05LP ...
Page 149: ... Document No C 61 00003 3 13 2 Base mounting bracket ...
Page 150: ... Document No C 61 00003 3 13 3 Rear mounting bracket ...
Page 151: ... Document No C 61 00003 3 13 4 Cover Protection Bracket ...
Page 152: ... Document No C 61 00003 3 14 EC Declaration of conformity ...
Page 153: ... Document No C 61 00003 3 ...