Document No: C-61-00003-3
7.14 Function configuration
User can configure various functions of the UAM through UAM project designer. Click on the [Function]
tab to display the list of configurable functions (Figure 7-40). Put a check mark to activate the corresponding
function (refer to section 7.9.1 for detail). List of configurable functions are shown below. There are some
functions which cannot be used simultaneously *
1
. In such case, if one function is selected the other will be
displayed in gray and cannot be selected. Also, maximum configurable area will change depending on the
selected function. Confirm the pin assignment setting as it automatically changes according to the selected
function.
Sensing *
2
EDM
Interlock
Reference Monitor
Muting
Area Sequence
Master Slave
Encoder Input
Figure 7-40 Function information
*
1
:
Muting and encoder, Muting and Interlock, Muting and Master slave functions cannot be configured simultaneously.
Encoder input cannot be configured when dual protection mode is selected.
*
2:
Sensing is the basic setting of the sensor therefore there is no check box
Summary of Contents for UAM-05LP
Page 1: ... Document No C 61 00003 3 ...
Page 104: ... Document No C 61 00003 3 Figure 7 33 b Function Figure7 33 c Area ...
Page 107: ... Document No C 61 00003 3 Figure 7 36 a Project report tab Figure 7 36 b Error report tab ...
Page 148: ... Document No C 61 00003 3 13 External dimension 13 1 UAM 05LP ...
Page 149: ... Document No C 61 00003 3 13 2 Base mounting bracket ...
Page 150: ... Document No C 61 00003 3 13 3 Rear mounting bracket ...
Page 151: ... Document No C 61 00003 3 13 4 Cover Protection Bracket ...
Page 152: ... Document No C 61 00003 3 14 EC Declaration of conformity ...
Page 153: ... Document No C 61 00003 3 ...