99
Comments:
Voltage Range is: 0.0 - 3.3V for ELECTRONIC BOX
C80
Calibration of the inner SAPE gauge arm
Options:
None.
Special function:
None.
Description:
Step 1:
Move gauge arm to calibration position 1 and adjust the distance potentiometers mechanically.
The voltage of the distance potentiometer is indicated in the right 3-dig fi eld
Gauge arm fully returned to home position. The
reading for distance sape must be:
3.10 – 3.15V
Place the gauge arm to the fl ange edge and adjust the diameter potentiometers mechanically:
the voltage of the diameter potentiometer is indicated in the left 3-digit fi eld.
Place the arm to
fl ange edge. The reading must
be:
2.60 – 2.63V