46
Ø
Remove gently the laser pointer assy from the machine.
Ø
Mount the new laser pointer assy and proper route each cable to its connector.
Ø
Mount the laser plastic cover.
Ø
Turn on the balancer.
Ø
Calibrate with C122.
Ø
Check if the balancer works fi ne.
Ø
Mount the weight tray.
4.26 CHECK AND REPLACEMENT OF HOOD SWITCH
"
: Medium and big philip screwdriver, 5mm wrench, electronic inclinometer.
6
: 1h
i
: Defective hood switch may cause the following malfunctions:
1. Lowering the wheel guard the wheel does not start.
2. The balancer shows E2
TO CHECK THE SWITCH
Ø
Check with service code C56. When the wheel guard is lowered it should show 100.
TO REPLACE THE SWITCH
Ø
Disconnect the power supply from the back of the machine.
Ø
Remove the weight tray.
Ø
Remove the cover from wheel guard holder.
Ø
Disconnect the Hood Switch from the PCB and remove the wiring from the connector.
Ø
Remove the two (2) screws holding the switch to the wheel guard box.
Ø
Install the new switch and route the wiring harness through the access hole.
Ø
Install the wiring into the connector.
Ø
Reverse procedure for installation.
Ø
Select C code C56 and make sure that the switch is working properly.
Ø
Make sure thet the switch must close the circuit when the wheel guard
has an angle among 14° to 12°.
SM HOF GEODYNA 7600 Rel.D