91
Clearing the entire error memory (step 2):
Press the Acknowledgment key to proceed to step 2.
Use the option selection to choose “1” and acknowledge with the Acknowledgment key.
Comments:
None
C43
Reset counters
Options.
0
:
No reset of counters
1
:
Reset of counters.
Special function:
None
Description:
During fi rst setting into operation in the factory the following counters and memories can be reset
simultaneously using this code:Total number of measuring runs
•
Number of measuring runs where balance quality was considered OK
•
Number of optimisations and minimisations
•
Number of measuring runs in service mode
•
Number of measuring runs since the last calibration
The error memory which can be called up using C28 will not be reset. To this end please use C28.
Comments:
None
C45
Unbalance Calculation Parameters
Options:
None
Special function:
None
Description:
This C code defi ne the start mode and automatically the necessary number of revolution for
measurement.
The Special function can be read out one below the other:
In step
1
: The balancing time is reduce automatically in case the machine is able to measure it in the fi rsts revolutions
of the spin.
0
:
Disable the Adaptive Measuring Cycle
1
:
Enable the Adaptive Measuring Cycle
In step
2
: Alternative algoritm to measure the 1st Harmonic of the unbalance.Faster then the previousi Fourier.
0
:
Disable the Goertzel algorithm
1
:
Enable the Goertzel algorithm
In step
3
: To reduce the acceleration of the spin avoiding excessive acceleration. Good for small wheels.
0
:
Disablee the Soft Start Function
1
:
Enable the Soft Start Function
In step
4
: Time among the reaching the balancing speed and the starting of the unbalance measurement.
Measurement delay after spin up can be controlled, by chosen the preferred value. Default value is:
Motorized Wheel Balancer Machine - 0,8
Comments:
This feature is available from BK Rev.2.0 or higher.
The selected mode of operation disappear when machine is turned off. To transfer the selection to the permanent
memory perform a C90 code.