4.7 CHECK AND REPLACEMENT OF THE POWER ENTRY MODULE 6.3A FUSES
"
:
Multimeter
, small fl at screwdrive.
6
:
30’
i
:
Defective fuses may cause the following malfunctions:
Turning the machine on, the machine does not show anything.
TO CHECK AND REPLACE THE FUSES
Ø
Turn the balancer off.
Ø
Unplug the power supply cable.
Ø
Remove the fuses holder from the power entry module
Ø
Remove the fuses from the holder.
Ø
Take the Voltmeter and select it in Ohm.
Ø
Make sure that there is continuity among the two ends.
Ø
If there is not the continuity, replace the fuse or the fuses with new ones of the same Amps and same voltage.
Ø
Insert the new fuses in the holder and install them on the entry power module.
4.8 CHECK AND REPLACEMENT OF THE IBP BOX F1 AND F2 F FUSE
"
:
Multimeter, big and medium Phillips screwdriver.
6
:
30’
i
:
Defective fuses may cause the following malfunctions:
Turning the machine on, the machine does not show anything.
TO CHECK AND REPLACE THE FUSES
Ø
Turn the balancer off.
Ø
Unplug the power supply cable from the balancer.
Ø
Remove the weight tray.
Ø
Access to the IBP board.
Ø
Lift the fuse with the screwdriver to remove it easily from its holder.
Ø
Take the Voltmeter and select it in Ohm.
Ø
Make sure that there is continuity among the two ends.
Ø
If there is no continuity, replace the fuse with new one of the same Amps and voltage.
Ø
Insert the new fuse in the holder and install the plastic cover.
Ø
Turn on the balancer and check if it works fi ne.
Ø
Turn off the balancer.
Ø
Mount the weight tray.
Ø
Turn on the balancer and check again if it is still working fi ne.