82
C
Description
92
Display of actual distance and diameter of inner SAPE/geodata
97
Conditioning of the solenoid brake
98
Display of angular position of power clamp pulley, incremental encoder test (see C74).
102
Performing a measuring run and indication of harmonic contents of the unbalance signals
103
Test of the transimpedance and unbalance signal amplifi ers
104
Test the RC time constant of the unbalance transducers
110
Indication of the operating voltages supplied by the power supply module.
115
Calibration of the unbalance measurement with test rotor only
120
Enable /disable laser pointer
122
Laser pointer calibration
123
Display the dignostic status of weigh laser board
130
Touch screen calibartion
6.3 ENTERING SERVICE C CODES AND OPTIONS
Ø
C code:
Enter the "FUNCTION" screen. The service menu is accessed by pressing and holding the STOP"
button for 5". The Service code will be displayed in the screen.
Ø
Note:
The service menu is for service personnel only. Not for customers. The last service code used
since power on is displayed.
Ø
Options:
Rotate the balancer shaft to choose an option of a C code.
Ø
Acknowledge:
Press OK key to acknowledge the option chosen.
Ø
Abort
:
Press ESC key to abort a C code.
Ø
Special function:
Press the "Further information" key to activate extra functionality on some C codes (e.g. C75).
Press “Reset” key to reset data (e.g. C28)
Press " CONFIRMATION / CONTINUES" to switch over to an alternative reading (e.g. C, 12,
C74).
SM HOF GEODYNA 7600 Rel.D
Summary of Contents for geodyna 7600
Page 1: ...geodyna 7600 Service Manual ...
Page 118: ...118 SM HOF GEODYNA 7600 Rel D ...