Measuring run:
START/STOP indicators are available.
6.4 SAVING SETTINGS FOR MODES OF OPERATION AND CALIBRATION DATA
C90 :
save calibration data
SYSTEM RESET:
The balancer is always reset after C47, C85, C86 have been carried out.
6.5 USER C CODES REFERENCE
C0
Load confi guration from default profi le
Options:
0
:
No action
1
:
Set default values
Special function:
None
Description:
Pressing the
Acknowledgment key resets the user settings to values defi ned under factory setting
profi le (default values). The chosen mode of operation can be transferred to the permanent memory
The following modes of operation are activated simultaneously by pressing the Acknowledgment key.
FUNCTION
STATUS / VALUE
CODE
Unbalance display
Dynamic
Wheel Dimansion
distance
= 115mm (SAPE)
diameter
= 15"
width
= 6,5"
Wheel type
Car in inches
Type 1
Weight placement
Normal
Resolution of unbalance readings
Low
0
C1
Suppression of minor unbalance readings
On
1
C2
Measurement units of the unbalance readings
Grams / Ounces
0 / 1
C3
Compensation of adaptor unbalance
Off
0
C4
Automatic braking on lifting the wheel guard
On
1
C5
Number of revolutions for measurement
5-25
10
C6
Threshold for unbalance suppression in grams/ounces
according to C3
3.5 -20 g
0.12 - 0.71 oz
C8
Position brake and indexing
On
1
C11
Start of measurement by closing wheel guard
On
1
C13
Actuation direction of pedal for clamping/releasing
Lifting
0
C26
Comments:
None