66
0X001037
LINE BELOW LIMIT
Check the main power supply with C55.
If the problem still persists:
Check the Power supply to wall plug
If the problem still persists:
Check the main power supply cord and plug.
If the problem still persists:
Check the main switch.
If the problem still persists:
Check power supply cable and connectors inside of the machine.
If the problem still persists:
Call Snap On
C Codes
C55
0X001038
MAIN SHAFT OPTOENCODER LED CURRENT ABOVE20 mA, TOO HIGH
Check the main shaft Optoencoder cable.
If the problem still persists:
Clean the main shaft Optoencoder band.
If the problem still persists:
Check the main shaft Optoencoder.
If the problem still persists:
Call Snap On.
C Codes
C74, C75, C85
0X001039
MAINSHAFT OPTOENCODER LED CURRENT LESS 16 mA, TOO LOW
Check the main shaft Optoencoder fl at cable.
If the problem still persists:
Clean the main shaft Optoencoder band.
If the problem still persists:
Check the main shaft Optoencoder.
If the problem still persists:
Call Snap On
C Codes
C74, C75, C85
0X001040
SAPE 1D LOW VOLT
Check the Distance potentiometer connector and cable.
If the problem still persists:
Check the Distance potentiometer
If the problem still persists:
Check the IBP box.
If the problem still persists:
Call Snap On
C Codes
C80, C81, C92, C115, C84, C88, C90
0X001041
SAPE 1D HIGH VOLT
Check the Distance potentiometer connector and cable.
If the problem still persists:
Check the Distance potentiometer
If the problem still persists:
Check the IBP box.
If the problem still persists:
Call Snap On
C Codes
C80, C81, C92, C115, C84, C88, C90