44
Ø
Mount the plastic wheel again checking the correct loop of the return cord.
Ø
Test SAPE assembly by pulling on the SAPE arm to it’s full out position several times.
Ø
With the SAPE arm in the HOME position select service code C80.
Ø
Hold the SAPE wheel firmly, using a flat blade screwdriver adjust the potentiometer referring to the paragraph of
C code C80, C81, C82, C90
4.24 CHECK AND REPLACEMENT OF DIAMETER POTENTIOMETER
"
: Medium and big philip screwdriver, 13 and 14mm wrenches, 3mm allen key.
6
: 1h
i
: Defective potentiometer may cause the following malfunctions:
1. The laser pointer does not work.
2. Turning the balancer on, the display show E50X (when C120 is 1).
3. The laser pointer is on, but it does not move.
4. Turning the balancer on the display shows E300.
TO CHECK THE POTENTIOMER
Ø
Check with service code C75, C80 and C92
TO REPLACE THE POTENTIOMETER
Ø
Disconnect the power supply from the machine.
Ø
Remove the weight tray.
Ø
Disconnect the 2D SAPE harness from X connector of the IBP box.
Ø
Remove the 10mm nut holding the SAPE wheel to the mounting bracket and slide the cog wheel off of the
potetiometer shaft.
Ø
Remove the conical bushing.
Ø
Remove the 13mm nut holding the potentiometer to the frame.