85
guard. After the measuring run state switches automatically to 1, the adaptor symbol comes up and the mode is quit.
Resetting the state to 0 cancels compensation of adaptor unbalance.
Compensation is also cancelled by calibration, readjustment by the operator, an optimisation run or by turning off the
machine.
Comments:
None
C5
Automatic braking when the wheel guard is opened
Options:
0 : No braking when wheel guard is lifted
1 * : Braking when wheel guard is lifted
Special function:
None
Description:
With status = 0, there is no braking action when the wheel guard is raised; but the drive is
switched off, so that lateral and radial run-out of the wheel can be observed. Safety goggles should be worn
when doing so. If the wheel guard is raised before the measurement run has been completed and if the mode
of operation «Starting a measurement run by closing the wheel guard» is set, the measurement run will be
re-started on closing the wheel guard again. After completion of the unbalance measurement and
observation of run-out, the rotation of the main shaft can be decelerated by pressing the STOP key.
The selected mode of operation can be transferred to the permanent memory.
Comments:
The asterisk "*“ marks the factory-adjusted default.
C6
Number of revolutions for measurement
Options:
5 to 25 : Number of revolutions per measuring run
10 revs/run: Factory-adjusted value
Special function:
None
Description
WARNING! Reducing the number of measurement revolutions will reduce the accuracy of measurement.
Measurement accuracy can be evaluated using test mode C63.
The chosen mode of operation can be transferred to the permanent memory.
Comments:
None
C8
Treshold value of suppression of minor unbalance reading in units selected with
C115
Options:
3.5 - 20g (0.12 - 0.71oz) : Threshold value
3.5g (0.12oz) : Factory-adjusted value
Special function:
None
Description:
To set a new value use the option selection. Finally press the Acknowledgment key to acknowledge
the entered value or press the Abort key to retain the former one.
To keep balance quality independent of weight placement, the OK indication is only visible if the unbalance readings
for the normal balancing mode (balance clips on rim fl anges) and the static unbalance are lower than the thresholds
set via C8. Therefore the rim width must be known for a correct assessment of the balance quality (and for
recommendation of optimisation).
If OK is displayed the unbalance readings will always be 0, irrespective of the selected balancing mode. If the