54
E3
Gauge arm not in home position
Code C28
Complaint
After turning on the balancer show E3.
Root cause
Inner SAPE gauge arm not in home position.
Weight tray not properly placed.
Distance potentiometer not calibrated.
Distance potentiometer disconnected from the IBP box.
Difective distance potentiometer cable.
Defective distance potentiometer.
Defective IBP box.
Service Code
C92, C80, C81, C115, C84, C88, C90.
Actions to do
Replace SAPE gauge arm in home position and press STOP or ESC key to continue.
Replace the weight tray.
Calibrate the distance potentiometer.
Re-connect the distance potentiometer to the IBP box.
Replace the distance potentiometer
Replace the IBP box.
E6
Calibration weight not attached to fl ange
Code C28
812560, 812561, 812565, 812566.
Complaint
During the calibration C115 or C83, at the end of one of the step 3 or 4 is displayed
E6
Root cause
Calibration weight not attached to the fl ange
Transducer loosened
Service Code
C75 (AdE1 and AdE2), C115, C84, C88; C90
Actions to do
Perform the calibration C115 with the weight on the fl ange.
Re-adjust the transducer and calibrate with C115, C84, C88; C90
E8
Valve position was not entered
Code C28
Complaint
During the Optimization / Minimization E8 comes up
Root cause
The Optimization / Minimization operation has been performed unless enter the valve
position
Service Code
Actions to do
Repeat the Optimization / Minimization operation
E9
Optimisation was carried out incorrectly
Code C28
Complaint
During the Optimization / Minimization E9 comes up
Root cause
The Optimization / Minimization operation has been carried out incorrectly.
Service Code
Actions to do
Repeat the Optimization / Minimization operation
SM HOF GEODYNA 7600 Rel.D