4.14 CHECK AND REPLACEMENT OF OPTOENCODER BOARD OF THE MAIN SHAFT
"
:
Medium and big Phillips screwdriver, scissors.
6
:
1h
i
:
Defective optoencoder board may cause the following malfunctions:
1. The balancer shows error codes with module C10.
2. Machine shows E300
3. The wheel balancer shows 001021
TO CHECK THE OPTOENCODER BOARD
Ø
Turn on the balancer.
Ø
Check the encoder with service code C74, C54, C75
REPLACEMENT OF THE OPTOENCODER BOARD
Ø
Turn the machine off.
Ø
Disconnect power
supply.
Ø
Remove the weight tray.
Ø
Disconnect the 10 Pin ribbon cable from the encoder PCB.
Ø
Remove all dirt from the region where the Optoencoder is positioned, preferably with a moisturized cloth.
Ø
Remove the phillip screw holding the encoder PCB to the shaft tube.
Ø
Clean the encoder board lens.
Ø
Clean the polygon ring
Ø
Clean the polygon ring with humid or dry cotton bud.
Use only water
.
Do not use alcohol glass cleaner, degreaser or any other
aggressive liquids: This kind of substances are too aggressive
for the polygonal ring.
NOTE: BE CAREFUL NOT TO LET FOREIGN DEBRIS FALL INSIDE
THE TUBE.
Ø
Install the encoder board.
Ø
Apply again the plastic protection immediately.
Ø
Connect Connector X3 onto the Optoencoder.