76
K CODE
81X160
81X161
81X162
81X163
81X164
81X165
81X166
81X167
81X168
81X169
81X16A
81X16B
81X16C
81X16D
DESCRIPTION
Communication with EEPROM through I2C bus is failed.
EXPLANATION
When the microprocessor wants to calculate the unbalances, it needs a lot of
data that stored in EEPROM. If the communication with EEPROM failed, it can
not do calculation.
ACTION
Check the plugs, connectors and cables between microprocessor control
board and main shaft encoder board. May need to change encoder board or
microprocessor board
C CODE
C74
K CODE
81X510
Calibration slug is missing
81X511
The mass of calibration slug is wrong
81X512
The calibration slug is put on wrong side.
DESCRIPTION
The user calibration fail.
EXPLANATION
The user calibration uses calibration slug to calibrate the balancer. The calibra-
tion slug should be properly used in different steps. If it is not properly used,
or the mass of calibration slug is not right, or it is put wrong side, one of these
code will be generated.
ACTION
Follow the user manual to repeat user calibration procedure.
Reload software, maybe the software collapses.
Check the output of transducers.
C CODE
C14, C64
K CODE
81X560
c1 value too low, if a user calibration tool assumed
81X561
c2 value too low, if a user calibration tool assumed
81X565
c1 value too low, if a 100g weight and calibration rotor assumed
81X566
c2 value too low, if a 100g weight and calibration rotor assumed
81X570
c1 value too high, if a calibration rotor only assumed
81X571
c2 value too high, if a calibration rotor only assumed
DESCRIPTION
The vectors c1 and c2 generated by transducers are no correct in factory cali-
bration procedure.
EXPLANATION
In factory calibration procedure, a very precise and accurate instrument called
proof rotor and 100 gram calibration weigh are used. These calibration tools
make the transducers produce certain outputs, we call them as vector c1 and
c2. If something is wrong, for example, the tools are used improperly, or the
transducer work improperly, the vectors c1 and c2 will out of their range. If the
software detected the c1 and c2 are not right, these diagnostic codes will be
generated.
ACTION
Followed instruction on the manual repeat the factory calibration carefully.
Make sure every step is right. If still can not pass the calibration and got dia-
gnostic code, it will be the transducer problem. Use C64 to check the outputs
of transducers.
In most case should re-torque the transducers. Or transducer(s) is bad, need
replace the transducer(s).
C CODE
C64, C115, C84, C88
SM HOF GEODYNA 7600 Rel.D