112
Step 1:
Press the “
START
” button to begin the measuring run.
Step 2:
If a Pruefrotor is used, screw the 100 gram weight on the left side of the Pruefrotor. If the value displayed
is not “100” in step 2 press and hold the “
ENTER VALUE
” key and rotate the shaft until the custom weight is
displayed.
ROTATE THE CALIBRATION TOOL WITH 100GR AT 12 O’CLOCK.
Press the “
OK
” key to enter the value of the test weight.
Step 3:
Press the “
START
” button to begin the measuring run.
Step 4:
Remove the 100 gram calibration weight and insert it into the
right hand plane of the Pruefrotor. Press the “
START
” key to
begin the measuring run.
SM HOF GEODYNA 7600 Rel.D
Summary of Contents for geodyna 7600
Page 1: ...geodyna 7600 Service Manual ...
Page 118: ...118 SM HOF GEODYNA 7600 Rel D ...