13.2 Input Specifications/Output Specifications/Measurement Specifications
208
(24) Voltage unbalance factor (negative-phase unbalance factor, zero-phase unbalance factor) (Uunb, Uunb0)
Measurement method
Calculated using various components of the 3-phase fundamental voltage
wave (line-to-line voltage) for 3-phase 3-wire (3P3W2M, 3P3W3M) and 3-phase
4-wire connections. (For details, see "13.8 Calculation Formula" (p.232))
The string "-----" will appear when the RMS voltage values of all three phases are zero.
Displayed item
Negative-phase unbalance factor (Uunb), zero-phase unbalance factor (Uunb0)
Measurement range
Component is V and unbalance factor is 0.00% to 100.00%.
Measurement accuracy
When the measurement frequency is set to 50 Hz/60 Hz,
±
0.15%
(0.0% to 5.0% range specified for IEC61000-4-30 performance testing)
Event threshold
0.0% to 100.0%
Event IN
Start of approx. 200 ms aggregation in which reading was greater than the threshold
Event OUT
Start of approx. 200 ms aggregation in which the reading was less than (threshold - hysteresis)
Multiple-phase system treatment
None
Saved waveforms
Event waveforms
(25) Current unbalance factor (negative-phase unbalance factor, zero-phase unbalance factor) (Iunb, Iunb0)
Measurement method
For 3-phase 3-wire (3P2W2M and 3P3W3M) and 3-phase 4-wire, calculated using 3-phase funda-
mental current component (For details, see "13.8 Calculation Formula" (p.232).)
The string "-----" will appear when the RMS current values of all three phases are zero.
Displayed item
Negative-phase unbalance factor (Iunb), zero-phase unbalance factor (Iunb0)
Measurement range
Component is A and unbalance factor is 0.00% to 100.00%.
Measurement accuracy
-
Event threshold
0.0% to 100.0%
Event IN
Start of approx. 200 ms aggregation in which reading was greater than the threshold
Event OUT
Start of approx. 200 ms aggregation in which the reading was less than (threshold - hysteresis)
Multiple-phase system treatment
None
Saved waveforms
Event waveforms
HIOKI PQ3198A961-03
Summary of Contents for PQ3198
Page 2: ...HIOKI PQ3198A961 03...
Page 6: ...Contents iv HIOKI PQ3198A961 03...
Page 20: ...Usage Notes 14 HIOKI PQ3198A961 03...
Page 44: ...2 3 Display Items and Screen Types 38 HIOKI PQ3198A961 03...
Page 58: ...3 8 Turning the Power On and Off Setting the Default Language 52 HIOKI PQ3198A961 03...
Page 102: ...5 8 Factory Settings 96 HIOKI PQ3198A961 03...
Page 198: ...12 4 Downloading Recorded Data to Computer 192 HIOKI PQ3198A961 03...
Page 264: ...14 4 Disposing of the Instrument 258 HIOKI PQ3198A961 03...
Page 296: ...A32 HIOKI PQ3198A961 03...
Page 299: ...Index Index 3 Index Wiring 73 Z Zero adjustment 53 Zero phase A28 HIOKI PQ3198A961 03...
Page 300: ...Index Index 4 HIOKI PQ3198A961 03...
Page 301: ...HIOKI PQ3198A961 03...
Page 302: ...HIOKI PQ3198A961 03...
Page 303: ...HIOKI PQ3198A961 03...
Page 304: ...www hioki com HIOKI PQ3198A961 03...