13.3 Screen Specifications
224
-3.
[TIME PLOT]
screen
(3) DMM display
Display screens and parameters
1. Power
: RMS voltage, RMS current, Active power, Reactive power, Apparent power, Power
factor/displacement power factor, Frequency 200 ms, Active energy, Reactive ener-
gy, K factor, Efficiency
2. Voltage : 10-sec frequency, RMS voltage, Voltage total harmonic distortion, Current waveform
peak value (positive, negative), Frequency 200 ms, High-order harmonic component,
Zero-sequence negative-sequence unbalance ratio
3. Current : RMS current, Current total harmonic distortion, Current waveform peak value (pos-
itive, negative), Frequency 200 ms, High-order harmonic component, Zero-sequence
negative-sequence unbalance ratio
(1) Trend graph display
Displayed screens
1-screen display/2-screen display/Integrated power display
Display update rate during
measurement
Every TIME PLOT interval
Displayed content
Additional display
Event occurrence point display function (not available on the [Integrated Power] screen)
Event jump function
Allows details for specified event to be analyzed on
[VIEW]
screen.
Time-series graph cursors
Yes
Displayed
screens
Displayed item
Channel
selection
Display parameters and
description
Remarks
1-screen
display
Freq/Freq10s/Upk+/Upk-/Ipk+/Ipk-/
Urms/UrmsAVG/Udc/Irms/IrmsAVG/
Idc/P/S/Q/PF/DPF/Uunb0/Uunb/
Iunb0/Iunb/UharmH/IharmH/Uthd-F/
Uthd-R/Ithd-F/Ithd-R/KF/Eff1/Eff2/
Msv1/Msv%1/Msv2/Msv%2
Time-series graph showing
the MAX, MIN, and AVG
values for 1 parameter
Display pa-
rameters are
limited based
on the record-
ing parameter
setting.
2-screen
display
Time-series graph showing
the MAX, MIN, and AVG
values for 2 parameters
Integrated
power display
WP+/WP-/WQLAG/WQLEAD
―
Time-series graph showing
1 parameter
(2) Detailed trend graph display (interval)
Displayed screens
Time series graph of maximum and minimum values for fluctuation data
Display update rate during
measurement
Every TIME PLOT interval
Displayed content
Select and display any 1 of Urms1/2, Irms1/2, Pinst, Frequency cycle, and Inrush cycle.
Additional display
Event threshold value display function, Event occurrence point display function
Event jump function
Allows details for specified event to be analyzed on
[VIEW]
screen.
Time-series graph cursors
Yes
(3) Harmonic trend graph display
Displayed screens
1-screen display
Display update rate during
measurement
Every TIME PLOT interval
Displayed content
Time series graph of maximum, minimum, and average values for up to 6 items
Additional display
Event occurrence point display function
Event jump function
Allows details for specified event to be analyzed on
[VIEW]
screen.
Time-series graph cursors
Yes
HIOKI PQ3198A961-03
Summary of Contents for PQ3198
Page 2: ...HIOKI PQ3198A961 03...
Page 6: ...Contents iv HIOKI PQ3198A961 03...
Page 20: ...Usage Notes 14 HIOKI PQ3198A961 03...
Page 44: ...2 3 Display Items and Screen Types 38 HIOKI PQ3198A961 03...
Page 58: ...3 8 Turning the Power On and Off Setting the Default Language 52 HIOKI PQ3198A961 03...
Page 102: ...5 8 Factory Settings 96 HIOKI PQ3198A961 03...
Page 198: ...12 4 Downloading Recorded Data to Computer 192 HIOKI PQ3198A961 03...
Page 264: ...14 4 Disposing of the Instrument 258 HIOKI PQ3198A961 03...
Page 296: ...A32 HIOKI PQ3198A961 03...
Page 299: ...Index Index 3 Index Wiring 73 Z Zero adjustment 53 Zero phase A28 HIOKI PQ3198A961 03...
Page 300: ...Index Index 4 HIOKI PQ3198A961 03...
Page 301: ...HIOKI PQ3198A961 03...
Page 302: ...HIOKI PQ3198A961 03...
Page 303: ...HIOKI PQ3198A961 03...
Page 304: ...www hioki com HIOKI PQ3198A961 03...