Appendix 10 Frequently Asked Questions
A
35
Appendix
How can I process acquired
data later with a spreadsheet
program?
Auto-saved files recorded in [Wave-
form(realtime)] mode to removable
storage can be quickly and conve-
niently converted to a text (CSV) file
with the Utility Logger rogram, which
can then be loaded into a spread-
sheet program.
Auto-saved files recorded in
[CSV(realtime)] mode can be direct-
ly loaded into a spreadsheet pro-
gram, but note that the data cannot
be reloaded into the HiLogger.
How can I load data from a CF
card onto the PC when it has
no CF card slot?
Data can be transferred to a PC us-
ing the supplied USB cable and the
USB Drive mode.
6.6, "Transferring
Data to a Computer
(USB Drive Mode)"
(p.110)
How can I create files every
hour, from 0:00 (ideal split
time)?
Set auto-saving
[Split Save]
to Peri-
odic (
[Ref Time]
).
”Automatic
Save”(p.47)
What is the file limit when auto
saving to removable storage?
Depending on file size and CF card
capacity, more than 1,000 files can
be saved in one folder, although only
1,000 can be displayed on the file
screen.
As the number of files increases, the
time required to start and stop mea-
surement also increases, so we rec-
ommend storing no more than 1,000
files, if possible.
(When saving, a folder named
"HIOKI_LR8431" is created, and
files with different data types are
saved in subfolders within it.)
6.1, "About Saving
and Loading Data"
(p.91)
Is data retained in internal
memory when I turn the power
off after measuring?
I did not use auto saving to re-
movable storage.
If the instrument is turned off with a
9780 Battery Pack with remaining
power connected or the Z1005 AC
Adapter connected, waveform data
will be backed up to the instrument's
internal memory. For the LR8431-20
with a fully charged 9780 Battery
Pack, the waveform backup time is
100 hours.
"Waveform backup
time function" (p.145)
Question
Remedial Action
Reference page
Summary of Contents for LR8431
Page 2: ......
Page 20: ...Operating Precautions 12...
Page 44: ...2 5 Zero Adjustment 36...
Page 74: ...3 7 Viewing All Channel Settings in a List 66...
Page 88: ...4 5 About Recording Operation 80...
Page 120: ...6 6 Transferring Data to a Computer USB Drive Mode 112...
Page 126: ...7 2 Numerical Value Calculation Expressions 118...
Page 136: ...8 3 Making System Settings 128...
Page 144: ...9 5 Synchronous Measurements with Multiple Instruments 136...
Page 154: ...Chapter 10 Specifications 146...
Page 198: ...Appendix 11 Pulse Input Circuit Diagram A40...
Page 202: ...Index Index 4...
Page 203: ......