![Hioki LR8410-20 Instruction Manual Download Page 172](http://html1.mh-extra.com/html/hioki/lr8410-20/lr8410-20_instruction-manual_2137134172.webp)
6.1 About Saving and Loading Data
160
1: Save waveform data in binary format if you intend to view it later in the instrument or on a PC with
the supplied Logger Utility program. Waveform data and some measurement-related settings
data are saved.
To save a waveform partially, specify a period by using A/B cursors before saving (p. 118).
When scaling has been set, the raw data (unscaled data) is recorded along with scaling informa-
tion in a binary format. When a previously saved file is loaded, the scaled data will be displayed.
However, you can also check the raw data by disabling scaling.
2: When opening a CSV file in a spreadsheet program, note that the number of rows that can be
loaded at one time is limited (p. A9).
3: BMP Format: This is a standard Windows
®
graphics format. These files can be handled by many
graphics programs.
4: Date (YY-MM-DD) folders are automatically created inside the DATA folder.
5: When saved manually. See "Appendix 3 File Naming" (p. A9) for file naming details.
*6: The TXT file extension is applied except when
[Separator:Comma]
is selected on the
[System]
screen.
7: When creating calculation-specific files, an underbar and a serial number (_n) is appended to the
file name, e.g., MEAS0001_1.CSV, MEAS0001_2.CSV, etc.
: Available/
-
: Not Available
File Type
File
Format
Folder Name
File Name*5
(Auto-numbered
from 1)
Save
Load
Auto
Man-
ual
LR
8410
PC
Setting Data
Binary
CONFIG
CONF0001.SET
-
-
Setting List
Binary
CONFIG
LIST001.BDL
-
-
Schedule
settings
Binary
CONFIG
LIST001.RCV
-
-
Waveform
Data
1
Binary
DATA\(date)
4
(e.g.: 08-07-30)
AUTO0001.MEM
WAVE0001.MEM
Text
2
DATA\(date)
4
(e.g.: 08-07-30)
AUTO0001.CSV
WAVE0001.CSV
*
6
-
Numerical
Calculation
Results
Text
2
MEASUREMENT
AUTO0001.CSV
MEAS0001.CSV
7
-
Captured
Screen Image
BMP
3
PICTURE
SCR00001.BMP
-
Depending on file size and SD memory card capacity, each folder can
store over 1,000 files. However, the file screen display is limited to a maxi-
mum of 1,000 files. Also, as more files are created, more time is needed to
start and stop recording. We recommend setting measurement criteria so
that the number of saved files stays below 1,000 whenever possible.
Summary of Contents for LR8410-20
Page 1: ......
Page 2: ......
Page 12: ...Contents x...
Page 32: ...Operating Precautions 20...
Page 78: ...2 7 Compensating for Input Circuit Offset Zero Adjustment 66...
Page 122: ...3 10 Viewing and Editing with the All Channel Settings List 110...
Page 138: ...4 3 Marking Waveforms and Searching Marks Search Function 126...
Page 222: ...9 4 Synchronous Measurements with Multiple instruments 210...
Page 316: ...13 3 Disposing of the instrument 304...
Page 360: ...Index Index 4...
Page 361: ......
Page 362: ......
Page 363: ......
Page 364: ......