Alarm Output Connections
DS-6700HUHI-K supports the open/close relay input as the alarm output mode. The alarm input can be selected to
NO
or
NC
. Different alarm output connection methods are applied to the AC or DC load. Please refer to the
following diagram:
Alarm output connections diagram:
Figure 1. 6
Alarm
Output Connections
Please note the different connections of JJ1 shown above.
For DC load, JJ1can be safely used both in
NC
and
NO
methods, and it is recommended to use within the limit of
12V/1A. For external AC input, JJ1 must be open. The motherboard provides two jumpers, each corresponding to
one alarm output. And both of two jumpers are factory set to be connected.