47
Enforcer V10 Programming Guide
APPENDIX B. INPUT TYPES
NUMBER & TYPE
OPERATION
00
Unused
Factory default. Input is programmed out of operation.
01
Fire
Active at all times. Audible response: Full (differentiated
Communicator: ‘Fire’ signal.
02
Gas
Active at all times. Audible Response: Full (differentiated
Communicator: ‘Gas’ signal.
03
HU#
Active at all times. Audible Response: Full (differentiated
Communicator: ‘Hold Up’ and ‘Input HU’ signals.
04
Silent HU#
Active at all times. Audible Response: None
Communicator: ‘Hold Up’ and ‘Input HU’ signals.
05
Tamper
When unset: Audible Response: Internal only Communicator:
‘Tamper’ signal. When set: Audible Response: Full (differentiated)
Communicator: ‘Tamper’ and ‘Unconfirmed’ signals.
06
Intruder
Active when set. Audible Response: Full
Communicator: ‘Intruder’ and ‘Unconfirmed’ signals.
07
Final Exit (FX)#
Active when set – initiates entry timer if system not unset before
entry time expires: Audible Response: Full.
Communicator: ‘Intruder’ and ‘Unconfirmed’ signals.
08
Entry Route (ER)
Active when set, except during entry time.
Audible Response: Full.
Communicator: ‘Intruder’ and ‘Unconfirmed’ signals.
09
ER (Part FX)
When fully set (A), acts as Entry route input, as above. When part set
(B,C,D), acts as Final Exit input, as above.
10
FX (Part ER)
When fully set (A), acts as Final Exit input, as above. When part set
(B,C,D), acts as Entry route input, as above.
11
PTS
Active during exit time to complete Setting procedure
No audible or communicator response.
Note: May be used to act as ‘doorbell’ by use of ‘chime’ attribute.
13
Day Alarm
When armed: Audible Response: Full; Communicator: ‘Instant’
signals. When disarmed: Audible Response: Programmable;
Communicator: ‘24hr Alarm’ signal (if programmed in Alarm
Responses menu).
16
Fault
When armed: Audible Response: Full; Communicator: ‘Instant’
signals. When disarmed: Audible Response: Programmable;
Communicator: ‘24hr Alarm’ signal (if programmed in Alarm
Responses menu).